Notifications
You must be signed in to change notification settings - Fork 30
/
ESPHome-3P-Sunsynk-Deye.yaml
1333 lines (1209 loc) · 40 KB
/
ESPHome-3P-Sunsynk-Deye.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
##########################WARNING HAS NOT BEEN TESTED USE AT YOUR OWN RISK ########################################
# Based on https://github.com/kellerza/sunsynk/blob/main/src/sunsynk/definitions3ph.py
#
substitutions:
settings_skipped_updates: "30"
devicename: sunsynk
device_description: "Sunsynk RS485 Logger"
friendly_name: "SunSynk"
esphome:
name: $devicename
comment: '${device_description}'
esp32:
board: nodemcu-32s
framework:
type: arduino
# Enable logging
logger:
baud_rate: 0
# Enable Home Assistant API
api:
encryption:
key: !secret api_encryption_key
ota:
password: !secret ota_password_sunsynk
platform: esphome
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: '${devicename}'
password: !secret fallback_password
fast_connect: true
power_save_mode: none
captive_portal:
# Enable time component to reset energy at midnight
# https://esphome.io/components/time.html#home-assistant-time-source
time:
- platform: homeassistant
id: homeassistant_time
uart:
id: mod_bus
tx_pin: GPIO1
rx_pin: GPIO3
baud_rate: 9600
stop_bits: 1
modbus:
id: sunsynk_modbus
flow_control_pin: GPIO16
modbus_controller:
- id: sunsynk
address: 0x01
modbus_id: sunsynk_modbus
setup_priority: -10
update_interval: "15s"
command_throttle: "50ms"
############################################### BINARY SENSORS ########################################
binary_sensor:
- platform: modbus_controller # 552 Grid Connected Status
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Connected Status"
id: sunsynk_esphome_grid_connected_status
register_type: holding
address: 552
# SENSORS #
#######################################################################################################
############################################### BATTERY ###############################################
sensor:
- platform: modbus_controller # 586 Battery Temperature
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Temperature"
id: sunsynk_esphome_battery_temperature
register_type: holding
address: 586
unit_of_measurement: "°C"
accuracy_decimals: 1
device_class: temperature
state_class: measurement
value_type: U_WORD
filters:
- offset: -1000
- multiply: 0.1
- platform: modbus_controller # 587 Battery Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Voltage"
id: sunsynk_esphome_battery_voltage
register_type: holding
address: 587
unit_of_measurement: "V"
accuracy_decimals: 1
device_class: voltage
state_class: measurement
filters:
- multiply: 0.01
value_type: U_WORD
- platform: modbus_controller # 588 Battery SOC
modbus_controller_id: sunsynk
name: "${friendly_name} Battery SOC"
id: sunsynk_esphome_battery_soc
register_type: holding
address: 588
unit_of_measurement: "%"
accuracy_decimals: 0
device_class: battery
value_type: U_WORD
- platform: modbus_controller # 590 Battery Power
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Power"
id: sunsynk_esphome_battery_power
register_type: holding
address: 590
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
value_type: S_WORD
- platform: modbus_controller # 591 Battery Current
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Current"
id: sunsynk_esphome_battery_current
register_type: holding
address: 591
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 115 Battery Capacity Shutdown
modbus_controller_id: sunsynk
name: "${friendly_name} Battery Capacity Shutdown"
id: sunsynk_esphome_battery_capacity_shutdown
register_type: holding
address: 115
unit_of_measurement: "%"
accuracy_decimals: 0
device_class: battery
############################################### INVERTER ##############################################
- platform: modbus_controller # 636 Inverter Power
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Power"
id: sunsynk_esphome_inverter_power
register_type: holding
address: 636
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
value_type: S_WORD
- platform: modbus_controller # 633 Inverter L1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter L1 Power"
id: sunsynk_esphome_inverter_L1_power
register_type: holding
address: 633
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
value_type: S_WORD
- platform: modbus_controller # 634 Inverter L2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter L2 Power"
id: sunsynk_esphome_inverter_L2_power
register_type: holding
address: 634
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
value_type: S_WORD
- platform: modbus_controller # 635 Inverter L3 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter L3 Power"
id: sunsynk_esphome_inverter_L3_power
register_type: holding
address: 635
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
value_type: S_WORD
- platform: modbus_controller # 627 Inverter Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Voltage"
id: sunsynk_esphome_inverter_voltage
register_type: holding
address: 627
unit_of_measurement: "V"
accuracy_decimals: 1
device_class: voltage
state_class: measurement
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller # 638 Inverter Frequency
modbus_controller_id: sunsynk
name: "${friendly_name} Inverter Frequency"
id: sunsynk_esphome_inverter_frequency
register_type: holding
address: 638
unit_of_measurement: "Hz"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: U_WORD
state_class: measurement
############################################### GRID ##################################################
- platform: modbus_controller # 609 Grid Frequency
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Frequency"
id: sunsynk_esphome_grid_frequency
register_type: holding
address: 609
unit_of_measurement: "Hz"
accuracy_decimals: 2
filters:
- multiply: 0.01
value_type: U_WORD
state_class: measurement
- platform: modbus_controller # 625 Grid Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Power"
id: sunsynk_esphome_grid_power
register_type: holding
address: 625
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 622 Grid L1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L1 Power"
id: sunsynk_esphome_grid_power_L1
register_type: holding
address: 622
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 623 Grid L2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L2 Power"
id: sunsynk_esphome_grid_power_L2
register_type: holding
address: 623
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 624 Grid L3 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L3 Power"
id: sunsynk_esphome_grid_power_L3
register_type: holding
address: 624
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 600 Grid Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} Grid Voltage"
id: sunsynk_esphome_grid_voltage
register_type: holding
address: 600
unit_of_measurement: "V"
accuracy_decimals: 1
device_class: voltage
state_class: measurement
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller # 610 Grid L1 Current
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L1 Current"
id: sunsynk_esphome_grid_current_L1
register_type: holding
address: 610
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 611 Grid L2 Current
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L2 Current"
id: sunsynk_esphome_grid_current_L2
register_type: holding
address: 611
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 612 Grid L3 Current
modbus_controller_id: sunsynk
name: "${friendly_name} Grid L3 Current"
id: sunsynk_esphome_grid_current_L3
register_type: holding
address: 612
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
value_type: S_WORD
filters:
- multiply: 0.01
- platform: modbus_controller # 619 Grid CT Power
modbus_controller_id: sunsynk
name: "${friendly_name} Grid CT Power"
id: sunsynk_esphome_grid_ct_power
register_type: holding
address: 619
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
############################################### LOAD ################################################
- platform: modbus_controller # 653 Load Power
modbus_controller_id: sunsynk
name: "${friendly_name} Load Power"
id: sunsynk_esphome_load_power
register_type: holding
address: 653
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 650 Load L1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Load L1 Power"
id: sunsynk_esphome_load_l1_power
register_type: holding
address: 650
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 651 Load L2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Load L2 Power"
id: sunsynk_esphome_load_l2_power
register_type: holding
address: 651
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 651 Load L3 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Load L3 Power"
id: sunsynk_esphome_load_l3_power
register_type: holding
address: 652
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
############################################### SOLAR PV1 #############################################
- platform: modbus_controller # 672 PV1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} PV1 Power"
id: sunsynk_esphome_pv1_power
register_type: holding
address: 672
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 676 PV1 Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} PV1 Voltage"
id: sunsynk_esphome_pv1_voltage
register_type: holding
address: 676
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
accuracy_decimals: 1
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller # 677 PV1 Current
modbus_controller_id: sunsynk
name: "${friendly_name} PV1 Current"
id: sunsynk_esphome_pv1_current
register_type: holding
address: 677
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
filters:
- multiply: 0.1
value_type: U_WORD
############################################### SOLAR PV2 #############################################
- platform: modbus_controller # 673 PV2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} PV2 Power"
id: sunsynk_esphome_pv2_power
register_type: holding
address: 673
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 678 PV2 Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} PV2 Voltage"
id: sunsynk_esphome_pv2_voltage
register_type: holding
address: 678
unit_of_measurement: "V"
accuracy_decimals: 1
filters:
- multiply: 0.1
device_class: voltage
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 679 PV2 Current
modbus_controller_id: sunsynk
name: "${friendly_name} PV2 Current"
id: sunsynk_esphome_pv2_current
register_type: holding
address: 679
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
filters:
- multiply: 0.1
value_type: U_WORD
############################################### SOLAR PV3 #############################################
- platform: modbus_controller # 674 PV3 Power
modbus_controller_id: sunsynk
name: "${friendly_name} PV3 Power"
id: sunsynk_esphome_pv3_power
register_type: holding
address: 674
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 680 PV3 Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} PV3 Voltage"
id: sunsynk_esphome_pv3_voltage
register_type: holding
address: 680
unit_of_measurement: "V"
accuracy_decimals: 1
filters:
- multiply: 0.1
device_class: voltage
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 681 PV3 Current
modbus_controller_id: sunsynk
name: "${friendly_name} PV3 Current"
id: sunsynk_esphome_pv3_current
register_type: holding
address: 681
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
filters:
- multiply: 0.1
value_type: U_WORD
############################################### SOLAR PV4 #############################################
- platform: modbus_controller # 675 PV4 Power
modbus_controller_id: sunsynk
name: "${friendly_name} PV4 Power"
id: sunsynk_esphome_pv4_power
register_type: holding
address: 675
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 682 PV4 Voltage
modbus_controller_id: sunsynk
name: "${friendly_name} PV4 Voltage"
id: sunsynk_esphome_pv4_voltage
register_type: holding
address: 682
unit_of_measurement: "V"
accuracy_decimals: 1
filters:
- multiply: 0.1
device_class: voltage
state_class: measurement
value_type: U_WORD
- platform: modbus_controller # 683 PV4 Current
modbus_controller_id: sunsynk
name: "${friendly_name} PV4 Current"
id: sunsynk_esphome_pv4_current
register_type: holding
address: 683
unit_of_measurement: "A"
accuracy_decimals: 1
device_class: current
state_class: measurement
filters:
- multiply: 0.1
value_type: U_WORD
############################################### SOLAR TOTAL ###########################################
- platform: template # Sum of PV1 and PV2 to get total PV Power
name: "${friendly_name} Solar Power"
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
lambda: |-
return (id(sunsynk_esphome_pv1_power).state + id(sunsynk_esphome_pv2_power).state + id(sunsynk_esphome_pv3_power).state + id(sunsynk_esphome_pv4_power).state);
update_interval: 5s
############################################### OUTPUTS ###############################################
- platform: modbus_controller # 667 Gen Power
modbus_controller_id: sunsynk
name: "${friendly_name} Gen Power"
id: sunsynk_esphome_gen_power
register_type: holding
address: 667
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 664 Gen L1 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Gen L1 Power"
id: sunsynk_esphome_gen_l1_power
register_type: holding
address: 664
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 665 Gen L2 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Gen L2 Power"
id: sunsynk_esphome_gen_l2_power
register_type: holding
address: 665
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
- platform: modbus_controller # 666 Gen L3 Power
modbus_controller_id: sunsynk
name: "${friendly_name} Gen L3 Power"
id: sunsynk_esphome_gen_L3_power
register_type: holding
address: 666
unit_of_measurement: "W"
accuracy_decimals: 0
device_class: power
state_class: measurement
value_type: S_WORD
############################################### ENERGY ################################################
- platform: modbus_controller # 514 Day Battery Charge
modbus_controller_id: sunsynk
name: "${friendly_name} Day Battery Charge"
id: sunsynk_esphome_day_battery_charge
register_type: holding
address: 514
unit_of_measurement: "kWh"
accuracy_decimals: 1
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 515 Day Battery Discharge
modbus_controller_id: sunsynk
name: "${friendly_name} Day Battery Discharge"
id: sunsynk_esphome_day_battery_discharge
register_type: holding
address: 515
unit_of_measurement: "kWh"
accuracy_decimals: 1
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 516 Total Battery Charge
modbus_controller_id: sunsynk
name: "${friendly_name} Total Battery Charge"
id: sunsynk_esphome_total_battery_charge
register_type: holding
address: 516
unit_of_measurement: "kWh"
accuracy_decimals: 1
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller # 518 Total Battery Discharge
modbus_controller_id: sunsynk
name: "${friendly_name} Total Battery Discharge"
id: sunsynk_esphome_total_battery_discharge
register_type: holding
address: 518
unit_of_measurement: "kWh"
accuracy_decimals: 0
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller # 520 Day Grid Import
modbus_controller_id: sunsynk
name: "${friendly_name} Day Grid Import"
id: sunsynk_esphome_day_grid_import
register_type: holding
address: 520
unit_of_measurement: "kWh"
accuracy_decimals: 1
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 521 Day Grid Export
modbus_controller_id: sunsynk
name: "${friendly_name} Day Grid Export"
id: sunsynk_esphome_day_grid_export
register_type: holding
address: 521
unit_of_measurement: "kWh"
accuracy_decimals: 1
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 522 Total Grid Import
modbus_controller_id: sunsynk
name: "${friendly_name} Total Grid Import"
id: sunsynk_esphome_total_grid_import
register_type: holding
address: 522
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 524 Total Grid Export
modbus_controller_id: sunsynk
name: "${friendly_name} Total Grid Export"
id: sunsynk_esphome_total_grid_export
register_type: holding
address: 524
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_WORD
filters:
- multiply: 0.1
- platform: modbus_controller # 526 Day Load Energy
modbus_controller_id: sunsynk
name: "${friendly_name} Day Load Energy"
id: sunsynk_esphome_day_load_energy
register_type: holding
address: 526
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
filters:
- multiply: 0.1
value_type: U_WORD
- platform: modbus_controller # 527 Total Load Energy
modbus_controller_id: sunsynk
name: "${friendly_name} Total Load Energy"
id: sunsynk_esphome_total_load_energy
register_type: holding
address: 527
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
value_type: U_DWORD_R
filters:
- multiply: 0.1
- platform: modbus_controller # 534 Total PV Energy
modbus_controller_id: sunsynk
name: "${friendly_name} Total PV Energy"
id: sunsynk_esphome_total_pv_energy
register_type: holding
address: 534
unit_of_measurement: "kWh"
accuracy_decimals: 2
device_class: energy
state_class: total_increasing
filters:
- multiply: 0.1
value_type: U_DWORD_R
- platform: modbus_controller # 529 Day PV Energy
modbus_controller_id: sunsynk
name: "${friendly_name} Day PV Energy"
id: sunsynk_esphome_day_pv_energy
register_type: holding
address: 529
unit_of_measurement: "kWh"
accuracy_decimals: 1
device_class: energy
state_class: total_increasing
filters:
- multiply: 0.1
value_type: U_WORD
############################################### TEMPERATURE ################################################
- platform: modbus_controller # 540 DC Transformer Temperature
modbus_controller_id: sunsynk
name: "${friendly_name} DC Transformer Temperature"
id: sunsynk_esphome_dc_transformer_temperature
register_type: holding
address: 540
unit_of_measurement: "°C"
accuracy_decimals: 1
device_class: temperature
state_class: measurement
value_type: S_WORD
filters:
- offset: -1000
- multiply: 0.1
- platform: modbus_controller # 541 Radiator Temperature
modbus_controller_id: sunsynk
name: "${friendly_name} Radiator Temperature"
id: sunsynk_esphome_radiator_temperature
register_type: holding
address: 541
unit_of_measurement: "°C"
accuracy_decimals: 1
device_class: temperature
state_class: measurement
value_type: S_WORD
filters:
- offset: -1000
- multiply: 0.1
################################################ READ SETTINGS #############################################
- platform: modbus_controller # 148 System Mode Time 1
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Time1"
id: sunsynk_esphome_system_mode_time1
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 148
icon: "mdi:clock"
- platform: modbus_controller # 149 System Mode Time 2
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Time2"
id: sunsynk_esphome_system_mode_time2
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 149
icon: "mdi:clock"
- platform: modbus_controller # 150 System Mode Time 3
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Time3"
id: sunsynk_esphome_system_mode_time3
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 150
icon: "mdi:clock"
- platform: modbus_controller # 151 System Mode Time 4
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Time4"
id: sunsynk_esphome_system_mode_time4
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 151
icon: "mdi:clock"
- platform: modbus_controller # 152 System Mode Time 5
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Time5"
id: sunsynk_esphome_system_mode_time5
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 152
icon: "mdi:clock"
- platform: modbus_controller # 153 System Mode Time 6
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Time6"
id: sunsynk_esphome_system_mode_time6
register_type: holding
skip_updates: ${settings_skipped_updates}
address: 153
icon: "mdi:clock"
################################################ WRITE SETTINGS ############################################
switch:
- platform: modbus_controller # 145 Toggle Solar Sell
use_write_multiple: true
modbus_controller_id: sunsynk
name: "${friendly_name} Toggle Solar sell"
id: sunsynk_esphome_toggle_solar_sell
register_type: holding
address: 145
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 146 Toggle System Timer
use_write_multiple: true
modbus_controller_id: sunsynk
name: "${friendly_name} Toggle System Timer"
id: sunsynk_esphome_toggle_Time_of_Use
register_type: holding
address: 146
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 141 Priority Load
use_write_multiple: true
modbus_controller_id: sunsynk
name: "${friendly_name} Toggle Priority Load"
id: sunsynk_esphome_toggle_priority_load
register_type: holding
address: 141
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 172 System Mode Grid Charge Time 1
use_write_multiple: true
modbus_controller_id: sunsynk
name: "${friendly_name} System Mode Grid Charge Time1"
id: sunsynk_esphome_toggle_grid_charge_time1
register_type: holding
address: 172
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 173 System Mode Grid Charge Time 2
modbus_controller_id: sunsynk
use_write_multiple: true
name: "${friendly_name} System Mode Grid Charge Time2"
id: sunsynk_esphome_toggle_grid_charge_time2
register_type: holding
address: 173
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 174 System Mode Grid Charge Time 3
modbus_controller_id: sunsynk
use_write_multiple: true
name: "${friendly_name} System Mode Grid Charge Time3"
id: sunsynk_esphome_toggle_grid_charge_time3
register_type: holding
address: 174
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 175 System Mode Grid Charge Time 4
modbus_controller_id: sunsynk
use_write_multiple: true
name: "${friendly_name} System Mode Grid Charge Time4"
id: sunsynk_esphome_toggle_grid_charge_time4
register_type: holding
address: 175
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 176 System Mode Grid Charge Time 5
modbus_controller_id: sunsynk
use_write_multiple: true
name: "${friendly_name} System Mode Grid Charge Time5"
id: sunsynk_esphome_toggle_grid_charge_time5
register_type: holding
address: 176
bitmask: 1
icon: "mdi:toggle-switch"
- platform: modbus_controller # 177 System Mode Grid Charge Time 6
modbus_controller_id: sunsynk
use_write_multiple: true
name: "${friendly_name} System Mode Grid Charge Time6"
id: sunsynk_esphome_toggle_grid_charge_time6
register_type: holding
address: 177
bitmask: 1
icon: "mdi:toggle-switch"
number:
- platform: modbus_controller # 166 System Mode SoC Time 1
use_write_multiple: true
modbus_controller_id: sunsynk
id: sunsynk_esphome_set_soc_time1
name: "${friendly_name} System Mode SoC Time1"