Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathlr_floor.lua
136 lines (129 loc) · 5.84 KB
/
lr_floor.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
return {
active = true,
on = {
devices = {
-- temp sensors
't_ext', 'TH LR',
-- setpoints
'H Livingroom',
-- switches
'H/C',
-- heatpump control
'Heatpump cooling', 'Heatpump heating',
-- floors/radiators
'Floor livingroom'
}
},
data = {
hist_lr = { history = true, maxMinutes = 40 }
},
execute = function(dz, item)
t_ext = dz.devices('t_ext')
hco = dz.devices('H/C')
hpc = dz.devices('Heatpump cooling')
hph = dz.devices('Heatpump heating')
hysteresis_h = 0.1
hysteresis_l = 0.1
-- slope = 0.5
h_lr = dz.devices('H Livingroom')
r_lr = dz.devices('Floor livingroom')
t_lr = dz.devices('TH LR')
if item.name == 'TH LR' then
dz.log('update data.hist_lr')
dz.data.hist_lr.add(t_lr.temperature)
end
-- p_lr = dz.data.hist_lr.deltaSince('00:20:00', 1, 0) * 6 + t_lr.temperature
p_lr = (dz.data.hist_lr.avg(1,6) - dz.data.hist_lr.avg(21,26)) * 6 + dz.data.hist_lr.avg(1,6)
if p_lr == 0 then
p_lr = t_lr.temperature
dz.notify('t_lr sensor issue')
end
dz.log('lr t_ext.temperature ' .. t_ext.temperature)
dz.log('lr dz.variables(hd_lr).value ' .. dz.variables('hd_lr').value)
dz.log('lr dz.variables(hd_lr).lastUpdate.minutesAgo ' .. dz.variables('hd_lr').lastUpdate.minutesAgo)
dz.log('lr dz.variables(hph_delayed_off).value ' .. dz.variables('hph_delayed_off').value)
dz.log('lr dz.variables(hph_delayed_on).value ' .. dz.variables('hph_delayed_on').value)
dz.log('lr dz.variables(hph_delayed_on).lastUpdate.minutesAgo ' .. dz.variables('hph_delayed_on').lastUpdate.minutesAgo)
-- dz.log('lr dz.variables(hs_lr).value ' .. dz.variables('hs_lr').value)
dz.log('lr h_lr.setPoint ' .. h_lr.setPoint)
dz.log('lr hph.lastUpdate.minutesAgo ' .. hph.lastUpdate.minutesAgo)
dz.log('lr hph.state ' .. hph.state)
dz.log('lr lr_avg0 ' .. dz.data.hist_lr.avg(0,5))
dz.log('lr lr_avg20 ' .. dz.data.hist_lr.avg(20,25))
dz.log('lr p_lr ' .. p_lr)
dz.log('lr r_lr.state ' .. r_lr.state)
dz.log('lr t_lr ' .. t_lr.temperature)
-- dz.notify('lr t_lr ' .. t_lr.temperature)
if hco.state == 'Cooling' then
-- Need to make something here
dz.log('lr hco.state Coolingl')
elseif hco.state == 'Heating' then
-- Turning on - LR
-- if (t_lr.temperature < (h_lr.setPoint - hysteresis_l) or p_lr < (h_lr.setPoint - hysteresis_l)) and t_ext.temperature < 15.5 then
if t_lr.temperature < (h_lr.setPoint - hysteresis_l) or p_lr < (h_lr.setPoint - hysteresis_l) then
dz.log('lr heating demand')
if dz.variables('hd_lr').value == 0 then
dz.log('### hd_lr set 1')
dz.variables('hd_lr').set(1)
end
if r_lr.state == 'Off' then
dz.log('### r_lr.switchOn() 1 ###')
r_lr.switchOn()
end
-- Turning off LR
-- elseif (t_lr.temperature >= (h_lr.setPoint + hysteresis_h) and p_lr >= (h_lr.setPoint + hysteresis_h)) or t_ext.temperature > 15.5 then
elseif t_lr.temperature >= (h_lr.setPoint + hysteresis_h) and p_lr >= (h_lr.setPoint + hysteresis_h) then
dz.log('lr no heating demand')
if dz.variables('hd_lr').value ~= 0 then
dz.log('### hd_lr set 0 ###')
dz.variables('hd_lr').set(0)
end
-- if t_ext.temperature < 2.1 and (hph.state == 'Off' or dz.variables('hd_lr').lastUpdate.minutesAgo < 45) then
if t_ext.temperature < 2.1 and (hph.state == 'Off' and dz.variables('hph_delayed_on').value == 0) then
if r_lr.state == 'Off' then
dz.log('### r_lr.switchOn 2 ###')
r_lr.switchOn()
end
-- elseif (hph.state == 'Off' and dz.variables('hph_delayed_on').value == 0) or (hph.state == 'On' and (dz.variables('hd_lr').lastUpdate.minutesAgo > 45 or hph.lastUpdate.minutesAgo > 45)) then
elseif (hph.state == 'Off' and dz.variables('hph_delayed_on').value == 0) or (hph.state == 'On' and hph.lastUpdate.minutesAgo > 45) then
if r_lr.state == 'On' and r_lr.lastUpdate.minutesAgo > 5 then
dz.log('### r_lr.switchOff() 1 ###')
r_lr.switchOff()
end
end
else
dz.log('lr between hysteresis')
end
-- diff_setpoint_temp = ( h_lr.setPoint - t_lr.temperature)
-- if diff_setpoint_temp > 0.4 then hs = 0.9 -- slope + 0.4
-- elseif diff_setpoint_temp > 0.3 then hs = 0.8 -- slope + 0.3
-- elseif diff_setpoint_temp > 0.2 then hs = 0.7 -- slope + 0.2
-- elseif diff_setpoint_temp > 0.1 then hs = 0.6 -- slope + 0.1
-- elseif diff_setpoint_temp > 0 then hs = 0.5 -- slope
-- else hs = 0.4 -- slope - 0.1
-- end
-- if dz.variables('hs_lr').value ~= hs then
-- dz.log('### hs_lr set ' .. hs)
-- dz.variables('hs_lr').set(hs)
-- end
elseif hco.state == 'Off' then
if dz.variables('hph_delayed_on').value == 1 then
dz.log('### hph_delayed_on set 0 ###')
-- dz.variables('hph_delayed_on').set(0)
-- ToDo: figure out how to cancel turning hph on
end
-- Frost protection, open all valves
if t_ext.temperature < 2.1 then
if r_lr.state == 'Off' then
r_lr.switchOn()
end
elseif hpc.state == 'Off' and hpc.lastUpdate.minutesAgo > 3 and hph.state == 'Off' and hph.lastUpdate.minutesAgo > 3 then
if r_lr.state == 'On' then
r_lr.switchOff()
end
end
elseif hco.state == 'Manual' then
dz.log('hpc.state manual')
end
end
}