When launching Nebula when connected to AT128, the HW interface crashes with a segfault in GerLidarRange.
The AT128 TCP protocol does not support request code 0x23 (Get Azimuth FOV) and sends an error response, which Nebula does not check. Instead it assumes the payload is larger than the error response, resulting in a segfault.
The text was updated successfully, but these errors were encountered:
When launching Nebula when connected to AT128, the HW interface crashes with a segfault in GerLidarRange.
The AT128 TCP protocol does not support request code
0x23