Notifications
You must be signed in to change notification settings - Fork 0
/
README.devices
554 lines (426 loc) · 21.9 KB
/
README.devices
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
-------------------------------------------------------------------------------
README.devices
-------------------------------------------------------------------------------
This README contains various notes for users of libsigrok (or frontends
that are based on libsigrok) about device- and/or driver-specific issues.
Firmware
--------
Some devices supported by libsigrok need a firmware to be uploaded every time
the device is connected to the PC (usually via USB), before it can be used.
The default locations where libsigrok expects the firmware files are:
$SIGROK_FIRMWARE_DIR (environment variable)
$HOME/.local/share/sigrok-firmware
$prefix/share/sigrok-firmware
/usr/local/share/sigrok-firmware
/usr/share/sigrok-firmware
($prefix is usually /usr/local or /usr, depending on your ./configure options)
For further information see the section below and also:
http://sigrok.org/wiki/Firmware
Per-driver firmware requirements
--------------------------------
The following drivers/devices require a firmware upload upon connection:
- asix-sigma: The ASIX SIGMA and SIGMA2 require various firmware files,
depending on the settings used. These files are available from our
'sigrok-firmware' repository/project under a license which allows us
to redistribute them.
- dreamsourcelab-dslogic: The DreamSourceLab DSLogic/DSCope device series
requires various firmware files and FPGA bitstream files.
These can be extracted/downloaded from the vendor's GitHub repo using a
tool from our 'sigrok-util' repository/project.
- fx2lafw: Logic analyzers based on the Cypress FX2(LP) chip need the
firmware files from the 'sigrok-firmware-fx2lafw' repository/project.
The firmware is written from scratch and licensed under the GNU GPLv2+.
- hantek-6xxx: Certain oscilloscopes based on the Cypress FX2(LP) chip, such
as the Hantek 6022BE/6022BL, SainSmart DDS120, and Rocktech BM102, need the
firmware files from the 'sigrok-firmware-fx2lafw' repository/project.
The firmware is written from scratch and licensed under the GNU GPLv2+.
- hantek-dso: The Hantek DSO-2090 (and other supported models of the same
series of Hantek PC oscilloscopes) need firmware files.
These can be extracted from the vendor's Windows drivers using a tool
from our 'sigrok-util' repository/project.
- lecroy-logicstudio: The LeCroy LogicStudio requires FPGA bitstream files.
These can be extracted from the vendor's Windows software using a tool
from our 'sigrok-util' repository/project.
Additionally, it requires a Cypress FX2 firmware. This can be extracted
from the vendor's Windows software using another tool. Details:
http://sigrok.org/wiki/LeCroy_LogicStudio#Firmware
- saleae-logic16: The Saleae Logic16 needs a firmware file for the
Cypress FX2 chip in the device, as well as two FPGA bitstream files.
These can be extracted from the vendor's Linux application using a tool
from our 'sigrok-util' repository/project.
- saleae-logic-pro: The Saleae Logic Pro 16 needs a firmware file for the
Cypress FX3 chip in the device, as well as an FPGA bitstream file.
These can be extracted from the vendor's Linux application using a tool
from our 'sigrok-util' repository/project.
- sysclk-lwla:
- The Sysclk LWLA1034 requires various bitstream files.
These files are available from our 'sigrok-firmware' repository/project
under a license which allows us to redistribute them.
- The Sysclk LWLA1016 requires various bitstream files.
These can be extracted from the vendor's Windows drivers using a tool
from our 'sigrok-util' repository/project.
- sysclk-sla5032: The Sysclk SLA5032 needs an FPGA bitstream file.
This file can be copied (and renamed) from the Windows vendor software
installation directory. Details:
https://sigrok.org/wiki/Sysclk_SLA5032#Firmware
The following drivers/devices do not need any firmware upload:
- agilent-dmm
- appa-55ii
- arachnid-labs-re-load-pro
- atten-pps3xxx
- baylibre-acme
- beaglelogic
- brymen-dmm
- cem-dt-885x
- center-3xx (including all subdrivers)
- chronovu-la
- colead-slm
- conrad-digi-35-cpu
- demo
- fluke-45
- fluke-dmm
- ftdi-la
- gmc-mh-1x-2x (including all subdrivers)
- gwinstek-gds-800
- gwinstek-gpd
- hameg-hmo
- hantek-4032l
- hp-3457a
- hp-3478a
- hung-chang-dso-2100
- ikalogic-scanalogic2
- ikalogic-scanaplus
- ipdbg-la
- kecheng-kc-330b
- kern-scale
- korad-kaxxxxp
- lascar-el-usb
- lecroy-xstream
- link-mso19
- manson-hcs-3xxx
- maynuo-m97
- mic-985xx (including all subdrivers)
- microchip-pickit2
- mooshimeter-dmm
- motech-lps-30x
- norma-dmm
- openbench-logic-sniffer
- pce-322a
- pipistrello-ols
- rdtech-dps
- rigol-dg
- rigol-ds
- rohde-schwarz-sme-0x
- scpi-dmm
- scpi-pps
- serial-dmm (including all subdrivers)
- serial-lcr (including all subdrivers)
- siglent-sds
- teleinfo
- testo
- tondaj-sl-814
- uni-t-dmm (including all subdrivers)
- uni-t-ut32x
- yokogawa-dlm
- zeroplus-logic-cube
- zketech-ebd-usb
Specifying serial ports
-----------------------
Many devices supported by libsigrok use serial port based cables (real RS232
or USB-to-serial ones, CDC class) to connect to a PC. These serial cables are
supported by the libserialport library. Some vendors prefer to use HID chips
instead of CDC chips in their serial cables. These cables can get supported
by means of the hidapi library. Note that each chip type requires specific
support in the libsigrok library. Bluetooth connected devices may be supported
as well when they communicate by means of RFCOMM channels, or one of the
implemented BLE notification/indication approaches, and one of the Bluetooth
supporting platforms is used.
For all these devices, you need to specify the serial port they are connected
to (e.g. using the 'conn' option in sigrok-cli). It is not possible to scan
for such devices without specifying a serial port.
Example:
$ sigrok-cli --driver <somedriver>:conn=/dev/ttyUSB0 ...
$ sigrok-cli --driver <somedriver>:conn=hid/cp2110 ...
$ sigrok-cli --driver <somedriver>:conn=bt/rfcomm/01-23-45-67-89-ab ...
Formal syntax for serial communication:
- COM ports (RS232, USB CDC):
conn=<com-port>
- USB HID cables:
conn=hid[/<chip>]
conn=hid[/<chip>]/usb=<bus>.<dev>[.<if>]
conn=hid[/<chip>]/raw=<path>
conn=hid[/<chip>]/sn=<serno>
conn=hid[/<chip>]/iokit=<path>
chip can be: bu86x, ch9325, cp2110, victor
path may contain slashes
path and serno are "greedy" (span to the end of the spec)
- Bluetooth Classic and Bluetooth Low Energy (BLE):
conn=bt/<conn>/<addr>
conn can be: rfcomm, ble122, nrf51, cc254x
addr can be "dense" or separated, bt/cc254x/0123456789ab or
bt/rfcomm/11-22-33-44-55-66 or bt/ble122/88:6b:12:34:56:78
(note that colons may not be available when the conn= spec is taken
from a string that separates fields by colon, e.g. in the "--driver
<name>:conn=<spec>" example, that is why the dense form and the use
of dashes for separation are supported)
Some of the drivers implement a default for the connection. Some of the
drivers can auto-detect USB connected devices.
Beyond strict serial communication over COM ports (discussed above), the
conn= property can also address specific USB devices, as well as specify TCP
or VXI communication parameters. See these examples:
$ sigrok-cli --driver <somedriver>:conn=<vid>.<pid> ...
$ sigrok-cli --driver <somedriver>:conn=tcp-raw/<ipaddr>/<port> ...
$ sigrok-cli --driver <somedriver>:conn=vxi/<ipaddr> ...
$ sigrok-cli --driver <somedriver>:conn=usbtmc/<bus>.<addr> ...
Specifying serial port parameters
---------------------------------
Every serial device's driver has default serial port parameters like baud
rate, number of data bits, stop bits and handshake status. If a device requires
different parameters, pass them as option "serialcomm" with the driver name.
See libsigrok docs for the function serial_set_paramstr() for complete specs.
Example:
$ sigrok-cli --driver <somedriver>:conn=<someconn>:serialcomm=9600/7n1/dtr=1
Permissions of serial port based devices
----------------------------------------
When using devices supported by libsigrok that use serial port based cables
(real RS232 or USB-to-serial ones) to connect to a PC, you need to ensure
that the user running the libsigrok frontend has (read/write) permissions to
access the serial port device (e.g. /dev/ttyS0, /dev/ttyUSB0, and so on).
You can use 'chmod' to apply permissions as you see fit, and/or 'chown' to
change the owner of the serial port device to a certain user or group.
For USB-to-serial based devices, we recommended using our udev rules file
(see below for details).
Permissions for USB devices (udev rules files)
----------------------------------------------
When using USB-based devices supported by libsigrok, the user running the
libsigrok frontend (e.g. sigrok-cli) has to have (read/write) permissions
for the respective USB device.
On Linux, this is accomplished using udev rules. libsigrok ships a rules
file containing all supported devices which can be detected reliably
(generic USB-to-serial converters are omitted, as these are used for a wide
range of devices, e.g. GPS receivers, which are not handled by libsigrok).
The file is available in contrib/60-libsigrok.rules. This file just contains
the list of devices and flags these devices with ID_SIGROK="1". Access is
granted by the 61-libsigrok-plugdev.rules or 61-libsigrok-uaccess.rules files,
allowing access to members of the plugdev group or to currently logged in
users, respectively.
When using a libsigrok package from your favorite Linux distribution, the
files should already be installed in /usr/lib/udev/rules.d/, i.e.
60-libsigrok.rules and one of the access granting rules files. Use of
61-libsigrok-uaccess.rules is encouraged on systemd distributions.
The access policy can be locally overridden by placing appropriate rules in
/etc/udev/rules.d/, disabling or ammending the default policy. See the
udev documentation, e.g. man 7 udev, for details.
If you're building from source, you need to copy the file to the place
where udev will read these rules. Local rules should go to /etc/udev/rules.d.
Keep the file naming, otherwise interaction between the libsigrok rules and
rules shipped by the system will be broken.
Please consult the udev docs for details.
Non-default drivers for commodity chips
---------------------------------------
Some vendors include common USB chips in their products yet assign device
specific VID:PID pairs. Which results in the necessity for extra steps
before the serial port can be used:
- GW Instek VCP, found in GDM-8000 and probably other meters: Install the
vendors Windows driver to get access to a COM port. Or force the driver
assignment on Linux:
# modprobe cp210x
# echo 2184 0030 > /sys/bus/usb-serial/drivers/cp210x/new_id
Cypress FX2 based devices
-------------------------
Devices using the Cypress FX2(LP) chip without any specific USB VID/PID will
be enumerated with VID/PID 04b4:8613 (the default for "unconfigured FX2").
These are usually "FX2 eval boards" (that can also be used as LAs, though).
On Linux, the 'usbtest' driver will usually grab such devices, and they will
thus not be usable by libsigrok (and frontends).
You can fix this by running 'rmmod usbtest' as root before using the device.
UNI-T DMM (and rebranded models) cables
---------------------------------------
UNI-T multimeters (and rebranded devices, e.g. some Voltcraft models) can
ship with different PC connectivity cables:
- UT-D02 (RS232 cable)
- UT-D04 (USB/HID cable with Hoitek HE2325U chip, USB VID/PID 04fa:2490)
- UT-D04 (USB/HID cable with WCH CH9325 chip, USB VID/PID 1a86:e008)
- UT-D07 (Bluetooth adapter, ISSC BL79 BLETR chip)
- UT-D09 (USB/HID cable with SiL CP2110 chip, USB VID/PID 10c4:ea80)
The above cables are all physically compatible (same IR connector shape)
with all/most currently known UNI-T multimeters. For example, you can
use either of the UT-D04 USB/HID cables or the UT-D02 RS232 cable with
the UNI-T UT61D multimeter.
When using the UT-D02 RS232 cable with any of the supported UNI-T DMMs,
you have to use the respective driver with a '-ser' drivername suffix
(internally all of these models are handled by the 'serial-dmm' driver).
You also need to specify the serial port via the 'conn' option, e.g.
/dev/ttyUSB0 (attached via a USB-to-serial cable) or /dev/ttyS0 (actual
RS232 port) on Linux (see above).
Finally, the user running the frontend (e.g. sigrok-cli) also needs
permissions to access the respective serial port (see above).
Examples (sigrok-cli):
$ sigrok-cli --driver uni-t-ut61e-ser:conn=/dev/ttyUSB0 ...
$ sigrok-cli --driver voltcraft-vc820-ser:conn=/dev/ttyS0 ...
When using any of the UT-D04 USB/HID cables you have to use the respective
driver _without_ the '-ser' drivername suffix (internally all of these models
are handled by the 'uni-t-dmm' driver).
You also need to specify the USB vendor/device IDs of the cable.
Autodetection is not possible here, since various other products use the
USB VID/PID of those cables too, and there is no way to distinguish them.
Since the UT-D04 cables are USB based (but don't use a USB-to-serial chip)
there is no need to specify a serial port via 'conn', of course.
However, the user running the frontend does also need to have permissions
to access the respective USB device (see above).
Examples (sigrok-cli):
$ sigrok-cli --driver uni-t-ut61e:conn=1a86.e008 ...
$ sigrok-cli --driver voltcraft-vc820:conn=04fa.2490 ...
UNI-T UT-D04 cable issue on Linux
---------------------------------
The UNI-T UT-D04 cable with Hoitek HE2325U (or WCH CH9325) chip seems to have
a very specific problem on Linux. Apparently it requires to be put into
suspend (and woken up again) before it is usable. This seems to be a
Linux-only issue, Windows is not affected by this since apparently the
Windows kernel does this for every USB device, always.
Thus, if you want to use any of the UNI-T DMMs with this specific cable,
you'll have to run the following script (as root) once, every time you attach
the cable via USB. The script was written by Ralf Burger.
See also: http://erste.de/UT61/index.html
#!/bin/bash
for dat in /sys/bus/usb/devices/*; do
if test -e $dat/manufacturer; then
grep "WCH.CN" $dat/manufacturer > /dev/null && echo auto > ${dat}/power/level && echo 0 > ${dat}/power/autosuspend
fi
done
Enabling multimeter / data logger measurement output
----------------------------------------------------
Some multimeters or data loggers will not start outputting measurement data
unless a certain action has been performed by the user beforehand. This is
usually mentioned in the vendor manual of the respective device, but here's
a short list for convenience:
- BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
interface panel on top.
- Brymen BM257s: Press HOLD during power-on.
- Digitek DT4000ZC: Briefly press the "RS232" button.
- EEVBlog 121GW: Hold "1ms PEAK" until the "BT" indicator is shown.
- ES51919 based LCR meters (DER EE DE-5000, PeakTech 2170, UNI-T UT612):
Press the button with the "RS232" or "USB" or "PC link" label (usually
the "up" cursor button).
- Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
- Power on the device with the "DATA" button pressed.
- Metrahit 2x devices must be configured for the respective interface type.
- Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
- 'BD232' interface:
The multimeter must be configured for the respective interface type.
- 'SI232-II' interface ("PC Mode"):
The multimeter must be configured for interface type 'BD232' (all),
'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
be configured to the same baud rate as the host (default 9600).
Multimeter and interface must be configured to the same address.
- GW Instek GDM-397: Press the "REL/RS232C (USB)" button for roughly 1 second.
- GW Instek VCP: See the discussion on manual driver assignment to common
USB to UART chips with non-default USB identification.
- MASTECH MS6514: Press the "Setup/PC-Link" button for roughly 3 seconds.
- Metrix MX56C: Press the PRINT button to have the meter send acquisition
data via IR. Hold the PRINT button to adjust the meter's transmission
interval.
- Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
on the device with "FUNC" pressed (to power the interface from the DMM).
- PCE PCE-DM32: Briefly press the "RS232" button.
- RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
- TekPower TP4000ZC: Briefly press the "RS232" button.
- Tenma 72-7750: Briefly press the "RS232C" button.
- UNI-T UT60G: Briefly press the "RS232C" button.
- UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
- UNI-T UT71x: Press the "SEND/-/MAXMIN" button for roughly 1 second.
Briefly pressing the "EXIT" button leaves this mode again.
- UNI-T UT181A: In the "SETUP" menu set "Communication" to "ON".
- UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
appears that in practice you don't have to press the button (at least on
some versions of the device), simply connect the device via USB.
- V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
- Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
- Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
- Voltcraft VC-870: Press the "REL/PC" button for roughly 1 second.
ChronoVu LA8/LA16 USB VID/PIDs
------------------------------
The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously,
the device shipped with a USB VID/PID of 0403:6001, which is the standard ID
for FTDI FT232 USB chips.
Since this made it hard to distinguish the LA8/LA16 from any other device
with this FTDI chip connected to the PC, the vendor later shipped the
device with a USB VID/PID of 0403:8867.
The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and
automatically finds devices with either VID/PID pair.
OLS
---
The Dangerous Prototypes Openbench Logic Sniffer (OLS) logic analyzer
driver in libsigrok assumes a somewhat recent firmware has been flashed onto
the OLS (it doesn't need a firmware upload every time it's attached via USB,
since the firmware is stored in the device permanently).
The most recent firmware version that is tested is 3.07.
If you use any older firmware and your OLS is not found or is not working
properly, please upgrade to at least this firmware version. Check the
Dangerous Prototypes wiki for firmware upgrade instructions:
http://dangerousprototypes.com/docs/Logic_Sniffer_upgrade_procedure
Also, you need to specify a serial port for the OLS in the frontends, e.g.
using the 'conn' option in sigrok-cli, and you also need to have the
permissions to access the serial port (see above).
Example:
$ sigrok-cli --driver ols:conn=/dev/ttyACM0 ...
JTAGulator
----------
The Grand Idea Studio JTAGulator also implements the SUMP protocol and
thus is covered by the OLS driver. See the vendor's wiki on details how
to enable the Logic Analyzer mode of operation.
https://github.com/grandideastudio/jtagulator/wiki/Logic-Analyzer
Mooshimeter
-----------
The Mooshim Engineering Mooshimeter is controlled via Bluetooth Low Energy
(sometimes called Bluetooth 4.0), as such it requires a supported Bluetooth
interface available. The 'conn' option is required and must contain the
Bluetooth MAC address of the meter.
Example:
$ sigrok-cli --driver mooshimeter-dmm:conn=12-34-56-78-9A-BC ...
Since the Mooshimeter has no physical interface on the meter itself, the
channel configuration is set with the 'channel_config' option. The format
of this option is 'CH1,CH2' where each channel configuration has the form
'MODE:RANGE:ANALYSIS', with later parts being optional. In addition for
CLI compatibility, the ',' in the channels can also be a '/' and the ':' in
the individual configuration can be a ';'.
Available channel 1 modes:
- Current, A: Current in amps
- Temperature, T, K: Internal meter temperature in Kelvin
- Resistance, Ohm, W: Resistance in ohms
- Diode, D: Diode voltage
- Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max)
Available channel 2 modes:
- Voltage, V: Voltage
- Temperature, T, K: Internal meter temperature in Kelvin
- Resistance, Ohm, W: Resistance in ohms
- Diode, D: Diode voltage
- Aux, LV: Auxiliary (W input) low voltage sensor (1.2V max)
Only one channel can use the shared inputs at a time (e.g. if CH1 is measuring
resistance, CH2 cannot measure low voltage). Temperature is excepted from
this, so the meter can measure internal temperature and low voltage at the
same time.
Additionally, the meter can calculate the real power of both channels. This
generally only makes sense when CH1 is set to current and CH2 is set to a
voltage and so it is disabled by default. It must be enabled by enabling the
'P' channel (the third channel).
The range of the channel specification sets the maximum input for that channel
and is rounded up to the next value the meter itself supports. For example,
specifying 50 for the voltage will result in the actual maximum of 60.
Specifying 61 would result in 600. If omitted, sigrok will perform
auto-ranging of the channel by selecting the next greater value than the
latest maximum.
The analysis option sets how the meter reports its internal sampling buffer
to sigrok:
- Mean, DC: The default is a simple arithmetic mean of the sample buffer
- RMS, AC: The root mean square of the sample buffer
- Buf, Buffer, Samples: Report the entire sample buffer to sigrok. This
results in packets that contain all the samples in the buffer instead
of a single output value.
The size of the sample buffer is set with the 'avg_samples' option, while
the sampling rate is set with the 'samplerate' option. So the update rate
is avg_samples/samplerate. Both are rounded up to the next supported value
by the meter.
Example:
$ sigrok-cli -c channel_config="Aux;0.1/T" --driver mooshimeter-dmm...
$ sigrok-cli -c channel_config="A;;AC/V;;AC" --driver mooshimeter-dmm...