By default "Export Control User Limit" is based off the datasheet for your specific model. This is to make the slider on the number entity more manageable.
If you are running multiple Inverters at a property you will limit the total Grid Export to the maximum value "Export Control User Limit" is set to.
To allow maximum export you can override "Export Control User Limit" with "Config Max Export" (Disabled by default) you can then define a new upper limit which will apply to "Export Control User Limit"
Work in progress, some of this information may be inaccurate
For most people, this will be the most common mode of operation. In this mode, the home load will come from following sources in the given priority:
- Solar, for the amount of solar energy available
- Battery, as long as the battery State Of Charge (SOC) is above the "Battery Capacity" level (Default 10%)
- Grid, for the remaining missing power
Excess solar energy will go to Battery first, till the battery reaches the nearly full level. Once the battery is nearly full (95%), excess energy will go to the grid. Once the battery is completely full, all excess energy will go to the grid.
The power sent to the grid can be limited with the "Export Control User Limit" parameter. Battery charge and discharge currents can be limited with the "Battery Charge Max Current" and "Battery Discharge Max Current" parameters.
Allows Battery Charging from the Grid: Allow Grid Charge has 4 sub-modes:
- Both Forbidden: Does not charge from the grid. Inverter won't consume from batteries during time slots if set.
- Period 1 Allowed: Charges from Grid during time set. Inverter won't consume from batteries during this time slot if set & Period 2 Allowed.
- Period 2 Allowed: Charges from Grid during time set. Inverter won't consume from batteries during this time slot if set & Period 1 Allowed.
- Both Allowed: Charges from Grid during both time slots. Handy if you have more dynamic Grid Pricing.
Prevents battery discharging.
- Designed for EPS use if you for example of unstable Grid connection during set periods of the day.
- Handy for saving battery capacity for expensive Grid Periods.
In Feedin Priority mode, the home load comes from following sources in the given priority:
- Solar
- Grid The battery will not discharge.
Excess solar energy will go to the grid. If the grid power has been limited with the "Export Control User Limit" parameter, the remaining surplus power will go to the battery.
Warning, forced discharging may or may not increase the wear on your Inverter / Battery Setup. Use at own risk
Present from 0.6.0
Note, if you use "Back Up Mode" to prevent Battery discharge, remember to set
number.solax_grid_export_limit
back to zero
- Set
number.solax_grid_export_limit
to desired export level. 0 to -5000
- Set
select.solax_charger_use_mode
to "Back Up Mode"
- Set
select.solax_charger_use_mode
to "Self Use Mode" or Mode normally kept in.
Warning, forced discharging may or may not increase the wear on your Inverter / Battery Setup. Use at own risk
Present from 0.6.0
- Set
select.solax_export_duration
to the time period of dynamic export pricing. For example if your rate changes every 30 Minutes, set it to that.- Set
number.solax_battery_minimum_capacity_grid_tied
to the Minimum SOC you wish to discharge to.
- Trigger
button.solax_grid_export
- Set
number.solax_grid_export_limit
to desired export level. 0 to -6000- After time set in
select.solax_export_duration
the Inverter will return to normal mode of Operation, unless you triggerbutton.solax_grid_export
again.
- Set
select.solax_export_duration
to default. Reverts back to normal operation after 4 seconds.