# Type Fc (Hz) Q Gain (dB)
1 LowShelf 105 0.7 -3.7
2 Peaking 167 0.57 -5.9
3 Peaking 393 1.25 9.2
4 Peaking 2736 1.27 -4.1
5 Peaking 4259 2.57 6.1
6 Peaking 695 3.42 -1.3
7 Peaking 945 3.13 1.3
8 Peaking 6107 6 -3.3
9 Peaking 10000 1.09 3.8
10 HighShelf 10000 0.7 -5.5

Fixed Band EQs

When using fixed band (also called graphic) equalizer, apply preamp of -5.8 dB (if available) and set gains manually with these parameters.

# Type Fc (Hz) Q Gain (dB)
1 Peaking 31 1.41 -4.6
2 Peaking 62 1.41 -3.6
3 Peaking 125 1.41 -6.3
4 Peaking 250 1.41 0
5 Peaking 500 1.41 6
6 Peaking 1000 1.41 0.2
7 Peaking 2000 1.41 -3.8
8 Peaking 4000 1.41 2.5
9 Peaking 8000 1.41 1.1
10 Peaking 16000 1.41 -7.9