Configures and installs APCUPSd on Linux.
This playbook requires the following collections:
- community.general
!! Important: No validation is done on the values in the variables, if you input a value that is not supported by an APCUPSd configuration option, this role will not throw errors or warnings.
Variable | Purpose |
---|---|
apc_enable_fw_rules | Create firewall rules for the apcupsd service. If this variable is not set, but apc_nisip or apc_nisport is set or apc_upscable is of type ether then firewall rules will be created. |
apc_enable_killpwr | Adds -p to the command to run the apcupsd service which will kill power to the outlets on the APC UPS. |
apc_upsname | Determines the value for the UPSNAME option. |
apc_upscable | Determines the value for the UPSCABLE option. |
apc_upstype | Determines the value for the UPSTYPE option. |
apc_device | Determines the value for the DEVICE option. |
apc_scriptdir | Determines the value for the SCRIPTDIR option. |
apc_pwrfaildir | Determines the value for the PWRFAILDIR option. |
apc_nologindir | Determines the value for the NOLOGINDIR option. |
apc_onbatterydelay | Determines the value for the ONBATTERYDELAY option. |
apc_batterylevel | Determines the value for the BATTERYLEVEL option. |
apc_minutes | Determines the value for the MINUTES option. |
apc_timeout | Determines the value for the TIMEOUT option. |
apc_annoy | Determines the value for the ANNOY option. |
apc_annoydelay | Determines the value for the ANNOYDELAY option. |
apc_nologon | Determines the value for the NOLOGON option. |
apc_killdelay | Determines the value for the KILLDELAY option. |
apc_netserver | Determines the value for the NETSERVER option. |
apc_nisip | Determines the value for the NISIP option. |
apc_nisport | Determines the value for the NISPORT option. |
apc_eventsfile | Determines the value for the EVENTSFILE option. |
apc_eventsfilemax | Determines the value for the EVENTSFILEMAX option. |
apc_upsclass | Determines the value for the UPSCLASS option. |
apc_upsmode | Determines the value for the UPSMODE option. |
apc_stattime | Determines the value for the STATTIME option. |
apc_statfile | Determines the value for the STATFILE option. |
apc_logstats | Determines the value for the LOGSTATS option. |
apc_datatime | Determines the value for the DATATIME option. |
apc_facility | Determines the value for the FACILITY option. |
apc_battdate | Determines the value for the BATTDATE option. |
apc_sensitivity | Determines the value for the SENSITIVITY option. |
apc_wakeup | Determines the value for the WAKEUP option. |
apc_sleep | Determines the value for the SLEEP option. |
apc_lotransfer | Determines the value for the LOTRANSFER option. |
apc_hitransfer | Determines the value for the HITRANSFER option. |
apc_returncharge | Determines the value for the RETURNCHARGE option. |
apc_beepstate | Determines the value for the BEEPSTATE option. |
apc_lowbatt | Determines the value for the LOWBATT option. |
apc_outputvolts | Determines the value for the OUTPUTVOLTS option. |
apc_selftest | Determines the value for the SELFTEST option. |
apc_polltime | Determines the value for the POLLTIME option. |
MIT