Skip to content
This repository has been archived by the owner on Dec 8, 2023. It is now read-only.

Commit

Permalink
Merge pull request #45 from Azure/iot-edge-module-support
Browse files Browse the repository at this point in the history
Use _CreateFromEnvironment to create module handles
  • Loading branch information
dipannita08 authored Jan 8, 2021
2 parents bc43673 + b843627 commit 343601c
Show file tree
Hide file tree
Showing 2 changed files with 137 additions and 137 deletions.
270 changes: 135 additions & 135 deletions pnpbridge/ReadMe.md
Original file line number Diff line number Diff line change
Expand Up @@ -231,17 +231,17 @@ The following [readme](./src/adapters/src/Camera/readme.md) provides details on

## Building and Running the IoT Plug and Play bridge on an IoT device or gateway

| Platform | Supported |
| :-----------: | :-----------: |
| Windows | :heavy_check_mark: |
| Linux | :heavy_check_mark: |
| Platform | Supported |
| :------: | :----------------: |
| Windows | :heavy_check_mark: |
| Linux | :heavy_check_mark: |

### Prerequisites

To complete this section, you need to install the following software on your local machine:

* A development environment that supports compiling C++ such as: [Visual Studio (Community, Professional, or Enterprise)](https://visualstudio.microsoft.com/downloads/)- make sure that you include the NuGet package manager component and the Desktop Development with C++ workload when you install Visual Studio.
* [CMake](https://cmake.org/download/) - when you install CMake, select the option `Add CMake to the system PATH`.
* A development environment that supports compiling C++ such as: [Visual Studio (Community, Professional, or Enterprise)](https://visualstudio.microsoft.com/downloads/)- make sure that you include the NuGet package manager component and the Desktop Development with C++ workload when you install Visual Studio.
* [CMake](https://cmake.org/download/) - when you install CMake, select the option `Add CMake to the system PATH`.
* If you are building on Windows, you will also need to download Windows 17763 SDK: [https://developer.microsoft.com/en-US/windows/downloads/windows-10-sdk](https://developer.microsoft.com/en-US/windows/downloads/windows-10-sdk)

### Step 1: Get the required dependencies
Expand All @@ -254,7 +254,7 @@ After cloning the IoT Plug and Play bridge repo to your machine, open the "Devel
%REPO_DIR%\pnpbridge\> git submodule update --init --recursive
```

>Note: If you run into issues with the git clone sub module update failing, this is a known issue with Windows file paths and git see: [https://github.com/msysgit/git/pull/110](https://github.com/msysgit/git/pull/110) . You can try the following command to resolve the issue: `git config --system core.longpaths true`
>Note: If you run into issues with the git clone sub module update failing, this is a known issue with Windows file paths and git see: [https://github.com/msysgit/git/pull/110](https://github.com/msysgit/git/pull/110) . You can try the following command to resolve the issue: `git config --system core.longpaths true`
### Step 2: Build the Azure IoT Plug and Play bridge (on Windows)

Expand Down Expand Up @@ -341,16 +341,16 @@ Start IoT Plug and Play bridge by running it in a command prompt.
## Building and Running the IoT Plug and Play bridge as an edge module on IoT Edge Runtime

| Platform | Supported |
| :-----------: | :-----------: |
| Windows | :x: |
| Linux | :heavy_check_mark: |
| Platform | Supported |
| :------: | :----------------: |
| Windows | :x: |
| Linux | :heavy_check_mark: |

### Prerequisites

To complete this section, you need to install the following software on your local machine:

* A development environment that supports compiling C++ such as: [Visual Studio (Community, Professional, or Enterprise)](https://visualstudio.microsoft.com/downloads/)- make sure that you include the NuGet package manager component and the Desktop Development with C++ workload when you install Visual Studio.
* A development environment that supports compiling C++ such as: [Visual Studio (Community, Professional, or Enterprise)](https://visualstudio.microsoft.com/downloads/)- make sure that you include the NuGet package manager component and the Desktop Development with C++ workload when you install Visual Studio.
* [Azure IoT Edge for Visual Studio Code](https://marketplace.visualstudio.com/items?itemName=vsciot-vscode.azure-iot-edge), [Azure IoT Edge Tools for Visual Studio 2017](https://marketplace.visualstudio.com/items?itemName=vsc-iot.vsiotedgetools) or [Azure IoT Edge Tools for Visual Studio 2019](https://marketplace.visualstudio.com/items?itemName=vsc-iot.vs16iotedgetools)
* An Azure IoT Edge device on Linux
* A container engine such as [Docker](https://docs.docker.com/docker-for-windows/install/). IoT Edge modules are packaged as containers, so you need a container engine on your development machine to build and manage them.
Expand All @@ -366,7 +366,7 @@ After cloning the IoT Plug and Play bridge repo to your machine, open the "Devel
%REPO_DIR%\pnpbridge\> git submodule update --init --recursive
```

>Note: If you run into issues with the git clone sub module update failing, this is a known issue with Windows file paths and git see: [https://github.com/msysgit/git/pull/110](https://github.com/msysgit/git/pull/110) . You can try the following command to resolve the issue: `git config --system core.longpaths true`
>Note: If you run into issues with the git clone sub module update failing, this is a known issue with Windows file paths and git see: [https://github.com/msysgit/git/pull/110](https://github.com/msysgit/git/pull/110) . You can try the following command to resolve the issue: `git config --system core.longpaths true`
### Step 2: Setup Visual Studio tools
To make the building and creation of the module image easy, setup IoT extensions for Visual Studio using instructions [here](https://docs.microsoft.com/en-us/azure/iot-edge/tutorial-develop-for-linux#set-up-vs-code-and-tools).
Expand All @@ -387,31 +387,31 @@ Provide your container registry credentials to Docker so that it can push your c
Open pnpbridge\Dockerfile.amd64 (or the dockerfile corresponding to the architecture you want to use) and add/update the following environment variables:

```bash
ENV IOTHUB_DEVICE_CONNECTION_STRING="<ENTER CONNECTION STRING OF EDGE MODULE DEVICE>"
ENV PNP_BRIDGE_ROOT_MODEL_ID "dtmi:com:example:RootPnpBridgeSampleDevice;1"
ENV PNP_BRIDGE_HUB_TRACING_ENABLED "false"

ENV PNP_BRIDGE_ROOT_MODEL_ID "dtmi:com:example:RootPnpBridgeSampleDevice;1"
ENV PNP_BRIDGE_HUB_TRACING_ENABLED "false"
```

### Step 7: Build IoT Plug and Play Bridge module image
- Open pnpbridge\module.json and update the container registry/image information :
```JSON
{
  "$schema-version": "0.0.1",
  "description": "",
  "image": {
    "repository": "<ENTER CONTAINER REGISTRY URL>/<NAME OF IMAGE>",
    "tag": {
      "version": "<ENTER VERSION TAG>",
      "platforms": {
        "amd64": "./Dockerfile.amd64",
        "amd64.debug": "./Dockerfile.amd64.debug",
        "arm32v7": "./Dockerfile.arm32v7",
        "arm64v8": "./Dockerfile.arm64v8"
      }
    },
    "buildOptions": []
  },
  "language": "c"
"$schema-version": "0.0.1",
"description": "",
"image": {
"repository": "<ENTER CONTAINER REGISTRY URL>/<NAME OF IMAGE>",
"tag": {
"version": "<ENTER VERSION TAG>",
"platforms": {
"amd64": "./Dockerfile.amd64",
"amd64.debug": "./Dockerfile.amd64.debug",
"arm32v7": "./Dockerfile.arm32v7",
"arm64v8": "./Dockerfile.arm64v8"
}
},
"buildOptions": []
},
"language": "c"
}

```
Expand All @@ -424,123 +424,123 @@ Open pnpbridge\Dockerfile.amd64 (or the dockerfile corresponding to the architec
- Add the container registry credentials:
```JSON
{
  "registryCredentials": {
     "pnpbridge": {
        "username": "$CONTAINER_REGISTRY_USERNAME_pnpbridge",
        "password": "$CONTAINER_REGISTRY_PASSWORD_pnpbridge",
        "address": "<ADD CONTAINER REGISTRY ADDRESS HERE>"
    }
"registryCredentials": {
"pnpbridge": {
"username": "$CONTAINER_REGISTRY_USERNAME_pnpbridge",
"password": "$CONTAINER_REGISTRY_PASSWORD_pnpbridge",
"address": "<ADD CONTAINER REGISTRY ADDRESS HERE>"
}
}
}

```
- Add the image name of the module image you created:
```JSON
{
  "modules": {
          "ModulePnpBridge": {
            "version": "1.0",
            "type": "docker",
            "status": "running",
            "restartPolicy": "always",
            "settings": {
              "image": "<CONTAINER REGISTRY URL>/<NAME OF IMAGE>:<TAG>",
              "createOptions": "{}"
            }
          }
        }
"modules": {
"ModulePnpBridge": {
"version": "1.0",
"type": "docker",
"status": "running",
"restartPolicy": "always",
"settings": {
"image": "<CONTAINER REGISTRY URL>/<NAME OF IMAGE>:<TAG>",
"createOptions": "{}"
}
}
}
}

```

- Add the Pnp Bridge device & adapter configuration with desired property `PnpBridgeConfig`, for example, the following configues a Modbus TCP carbon monoxide sensor:
```JSON
{
  "ModulePnpBridge": {
      "properties.desired": {
        "PnpBridgeConfig": {
          "pnp_bridge_interface_components": [
            {
                "_comment": "Component 1 - Modbus Device",
                "pnp_bridge_component_name": "Co2Detector1",
                "pnp_bridge_adapter_id": "modbus-pnp-interface",
                "pnp_bridge_adapter_config": {
                    "unit_id": 1,
                    "tcp": {
                        "host": "10.159.29.2",
                        "port": 502
                    },
                    "modbus_identity": "DL679"
                }
            }
        ],
        "pnp_bridge_adapter_global_configs": {
            "modbus-pnp-interface": {
                "DL679": {
                    "telemetry": {
                        "co2": {
                            "startAddress": "40001",
                            "length": 1,
                            "dataType": "integer",
                            "defaultFrequency": 5000,
                            "conversionCoefficient": 1
                        },
                        "temperature": {
                            "startAddress": "40003",
                            "length": 1,
                            "dataType": "decimal",
                            "defaultFrequency": 5000,
                            "conversionCoefficient": 0.01
                        }
                    },
                    "properties": {
                        "firmwareVersion": {
                            "startAddress": "40482",
                            "length": 1,
                            "dataType": "hexstring",
                            "defaultFrequency": 60000,
                            "conversionCoefficient": 1,
                            "access": 1
                        },
                        "modelName": {
                            "startAddress": "40483",
                            "length": 2,
                            "dataType": "string",
                            "defaultFrequency": 60000,
                            "conversionCoefficient": 1,
                            "access": 1
                        },
                        "alarmStatus_co2": {
                            "startAddress": "00305",
                            "length": 1,
                            "dataType": "boolean",
                            "defaultFrequency": 1000,
                            "conversionCoefficient": 1,
                            "access": 1
                        },
                        "alarmThreshold_co2": {
                            "startAddress": "40225",
                            "length": 1,
                            "dataType": "integer",
                            "defaultFrequency": 30000,
                            "conversionCoefficient": 1,
                            "access": 2
                        }
                    },
                    "commands": {
                        "clearAlarm_co2": {
                            "startAddress": "00305",
                            "length": 1,
                            "dataType": "flag",
                            "conversionCoefficient": 1
                        }
                    }
                }
            }
         }
        }
      }
    }
"ModulePnpBridge": {
"properties.desired": {
"PnpBridgeConfig": {
"pnp_bridge_interface_components": [
{
"_comment": "Component 1 - Modbus Device",
"pnp_bridge_component_name": "Co2Detector1",
"pnp_bridge_adapter_id": "modbus-pnp-interface",
"pnp_bridge_adapter_config": {
"unit_id": 1,
"tcp": {
"host": "10.159.29.2",
"port": 502
},
"modbus_identity": "DL679"
}
}
],
"pnp_bridge_adapter_global_configs": {
"modbus-pnp-interface": {
"DL679": {
"telemetry": {
"co2": {
"startAddress": "40001",
"length": 1,
"dataType": "integer",
"defaultFrequency": 5000,
"conversionCoefficient": 1
},
"temperature": {
"startAddress": "40003",
"length": 1,
"dataType": "decimal",
"defaultFrequency": 5000,
"conversionCoefficient": 0.01
}
},
"properties": {
"firmwareVersion": {
"startAddress": "40482",
"length": 1,
"dataType": "hexstring",
"defaultFrequency": 60000,
"conversionCoefficient": 1,
"access": 1
},
"modelName": {
"startAddress": "40483",
"length": 2,
"dataType": "string",
"defaultFrequency": 60000,
"conversionCoefficient": 1,
"access": 1
},
"alarmStatus_co2": {
"startAddress": "00305",
"length": 1,
"dataType": "boolean",
"defaultFrequency": 1000,
"conversionCoefficient": 1,
"access": 1
},
"alarmThreshold_co2": {
"startAddress": "40225",
"length": 1,
"dataType": "integer",
"defaultFrequency": 30000,
"conversionCoefficient": 1,
"access": 2
}
},
"commands": {
"clearAlarm_co2": {
"startAddress": "00305",
"length": 1,
"dataType": "flag",
"conversionCoefficient": 1
}
}
}
}
}
}
}
}
}

```
Expand Down
4 changes: 2 additions & 2 deletions pnpbridge/src/pnpbridge/common/pnp_device_client.c
Original file line number Diff line number Diff line change
Expand Up @@ -141,9 +141,9 @@ static IOTHUB_MODULE_CLIENT_HANDLE AllocateModuleClientHandle(const PNP_DEVICE_C

if (pnpModuleConfiguration->securityType == PNP_CONNECTION_SECURITY_TYPE_CONNECTION_STRING)
{
if ((moduleClientHandle = IoTHubModuleClient_CreateFromConnectionString(pnpModuleConfiguration->u.connectionString, MQTT_Protocol)) == NULL)
if ((moduleClientHandle = IoTHubModuleClient_CreateFromEnvironment(MQTT_Protocol)) == NULL)
{
LogError("Failure creating IotHub module client. Hint: Check your connection string");
LogError("Failure creating IotHub module client from environment info.");
}
}

Expand Down