Skip to content

Commit

Permalink
Add more ignores
Browse files Browse the repository at this point in the history
  • Loading branch information
dmohns committed Jan 22, 2024
1 parent 3f8975b commit b32c143
Show file tree
Hide file tree
Showing 2 changed files with 6 additions and 0 deletions.
2 changes: 2 additions & 0 deletions docs/hardware/pcb_design.md
Original file line number Diff line number Diff line change
Expand Up @@ -60,12 +60,14 @@ Magnetic latching relay is used in place of electromagnetic relay due to cost,
3
reliability, power consumption, size. Comparison table is highlighted below.

<!-- prettier-ignore-start -->
| Electromagnetic relay | Magnetic latching relay|
| -------- | -------- |
| Terminal is susceptible to arching and carbon which eventually lead to relay failure. | Terminal is less susceptible to arching and carbon which eventually leadtorelay. |
| High cost in comparison to current handling capability. | Low cost in comparison to current handling capability. |
| Takes a lot of space. | Takes a very small considerable space. |
| Continuous supply power is needed to keep relay active | A single pulse of power is only needed to trigger the relay on or off. |
<!-- prettier-ignore-end -->

The above advantage of magnetic latching relay as compared to electromagnetic relayin terms of **cost, size, terminal carbonizing, power consumption and current
handling capability** is why we opted for a magnetic latching relay as opposed to using an electromagnetic relay.
Expand Down
4 changes: 4 additions & 0 deletions docs/hardware/product_specification.md
Original file line number Diff line number Diff line change
Expand Up @@ -35,6 +35,7 @@ Enter 20-digit token via keypad available on meter, the token is generated from

## Technical Parameter

<!-- prettier-ignore-start -->
| DESCRIPTION | SINGLE PHASE VALUE |
| -------- | -------- |
| Accuracy | CLASS 1 |
Expand All @@ -46,13 +47,16 @@ Enter 20-digit token via keypad available on meter, the token is generated from
| Communication Interface | DLMS / COSEMCompliance (GPRS) First Electric web API |
| Dimension | 18cm x 15cm |
| Display: | LCD 16x2 |
<!-- prettier-ignore-end -->

### Indicator

<!-- prettier-ignore-start -->
| Indicator | Description |
| -- | -- |
| Credit Indicator | Bi-color LED (red) <br> Green LED light on when credit is in highlevel <br> Red LED light on when credit is low <br> Red LED blinks when credit has finished |
| Alarm indicator | The indicator blinks when event occur, event such as overload, low voltage, low credit or credit exhausted. |
<!-- prettier-ignore-end -->

## Communication devices

Expand Down

0 comments on commit b32c143