Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

ENERGY STAR Update: Implement ES SFNH National v3.3 & ES MFNC National v1.3 #765

Draft
wants to merge 41 commits into
base: master
Choose a base branch
from

Conversation

bpark1327
Copy link
Collaborator

@bpark1327 bpark1327 commented Jan 24, 2025

Pull Request Description

Checklist

Not all may apply:

  • OS-HPXML git subtree has been pulled
  • 301validator.xml has been updated (reference EPvalidator.xml)
  • Sample files have been added/updated (openstudio tasks.rb update_hpxmls)
  • Tests have been added/updated (e.g., rulesets\tests and/or workflow/tests/*_test.rb)
  • Documentation has been updated
  • Changelog has been updated
  • openstudio tasks.rb update_measures has been run
  • No unexpected changes to simulation results on CI

@bpark1327 bpark1327 self-assigned this Jan 24, 2025
Copy link
Collaborator

@shorowit shorowit left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Let's bump the ENERGY STAR version in all the real/sample files. I think that's done here and here.

Then we should compare the new ERI Targets to the previous version and make sure they make sense.

Copy link
Collaborator

@shorowit shorowit left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Need to see if there are updated EPA tests for 3.3/1.3.

@bpark1327
Copy link
Collaborator Author

bpark1327 commented Feb 13, 2025

image
Looked at changes in the ERI score of Real Homes' ES Reference Home due to updates to ES SFNC v3.3 and MFNC v1.3. I examined two extreme cases (house015 and house077).

  old ERI new ERI bldg type iecc climate zone diff. in inputs
house015.xml 46.41 48.43 SF 5 ceiling ufactor 0.024 -> 0.026; windows ufactor 0.27->0.25; HSPF 9.2->9.5; air defect ratio -20% -> -7.5%; dishwasher 270 -> 240 kWh/yr; refrigerator 450 -> 655 kWh/yr
house077.xml 55.89 44.08 MF 6 Lighting Tier I -> Tier II; Dishwasher 270 -> 240 kWh/yr; Water Heating UEF 1.49 -> 2.5; Ventilation fan exhaust only 2.8 cfm/W -> HRV 1.2 cfm/W; airflow defect ratio -20% -> -7.5%; windows ufactor 0.27 -> 0.25; Infiltration 0.3 -> 0.27 cfm50/sqft

@bpark1327
Copy link
Collaborator Author

bpark1327 commented Feb 13, 2025

EPA reported that National v3.3 results in an ERI between 45 - 50 for ~70% of homes that were modeled.
Among our real home models (SF only), 51% fell within 45 - 50 range. The ERI range of the real home models is 42.5 - 58.7.

ERI Range EPA % of Homes Modeled NREL % of Homes Modeled (real_homes)
<45 6% 7%
45 to <50 69% 43%
50 to <55 24% 41%
≥55 0% 9%