Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Latest OS-HPXML #1187

Merged
merged 12 commits into from
Dec 21, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
8 changes: 8 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,3 +1,11 @@
## ResStock v3.3.0 (pending)

Features
- Updates and enhancements to the ground source heat pump model; ability to describe detailed geothermal loop inputs ([#1187](https://github.com/NREL/resstock/pull/1187))

Fixes
-

## ResStock v3.2.0
###### December 19, 2023 - [Diff](https://github.com/NREL/resstock/compare/v3.1.1...v3.2.0)

Expand Down
140 changes: 136 additions & 4 deletions docs/read_the_docs/source/workflow_inputs/characteristics.rst
Original file line number Diff line number Diff line change
Expand Up @@ -3034,12 +3034,24 @@ Arguments
- Type
- Choices
- Description
* - ``site_soil_and_moisture_type``
- false
-
- Choice
- "auto", "clay, dry", "clay, mixed", "clay, wet", "gravel, dry", "gravel, mixed", "gravel, wet", "loam, dry", "loam, mixed", "loam, wet", "sand, dry", "sand, mixed", "sand, wet", "silt, dry", "silt, mixed", "silt, wet", "unknown, dry", "unknown, mixed", "unknown, wet"
- Type of soil and moisture. This is used to inform ground conductivity and diffusivity. If not provided, the OS-HPXML default (see `HPXML Site <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site>`_) is used.
* - ``site_ground_conductivity``
- false
- Btu/hr-ft-F
- Double
- "auto"
- Conductivity of the ground soil. If not provided, the OS-HPXML default (see `HPXML Site <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site>`_) is used.
-
- Conductivity of the ground soil. If provided, overrides the previous site and moisture type input.
* - ``site_ground_diffusivity``
- false
- ft^2/hr
- Double
-
- Diffusivity of the ground soil. If provided, overrides the previous site and moisture type input.

.. _hvac_cooling_efficiency:

Expand Down Expand Up @@ -3105,7 +3117,7 @@ Arguments
-
- Choice
- "auto", "single stage", "two stage", "variable speed"
- The compressor type of the cooling system. Only applies to central air conditioner. If not provided, the OS-HPXML default (see `Central Air Conditioner <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner>`_) is used.
- The compressor type of the cooling system. Only applies to central air conditioner and mini-split. If not provided, the OS-HPXML default (see `Central Air Conditioner <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner>`_, `Mini-Split Air Conditioner <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-air-conditioner>`_) is used.
* - ``cooling_system_cooling_sensible_heat_fraction``
- false
- Frac
Expand Down Expand Up @@ -3451,7 +3463,7 @@ Arguments
-
- Choice
- "auto", "single stage", "two stage", "variable speed"
- The compressor type of the heat pump. Only applies to air-to-air. If not provided, the OS-HPXML default (see `Air-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump>`_) is used.
- The compressor type of the heat pump. Only applies to air-to-air and mini-split. If not provided, the OS-HPXML default (see `Air-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump>`_, `Mini-Split Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-heat-pump>`_) is used.
* - ``heat_pump_cooling_sensible_heat_fraction``
- false
- Frac
Expand Down Expand Up @@ -3548,6 +3560,66 @@ Arguments
- Double
- "auto"
- Heat Pump crankcase heater power consumption in Watts. Applies only to air-to-air, mini-split, packaged terminal heat pump and room air conditioner with reverse cycle. If not provided, the OS-HPXML default (see `Air-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump>`_, `Mini-Split Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-heat-pump>`_, `Packaged Terminal Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#packaged-terminal-heat-pump>`_, `Room Air Conditioner w/ Reverse Cycle <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#room-air-conditioner-w-reverse-cycle>`_) is used.
* - ``geothermal_loop_configuration``
- false
-
- Choice
- "auto", "none", "vertical"
- Configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `Ground-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#ground-to-air-heat-pump>`_) is used.
* - ``geothermal_loop_borefield_configuration``
- false
-
- Choice
- "auto", "Rectangle", "Open Rectangle", "C", "L", "U", "Lopsided U"
- Borefield configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_loop_flow``
- false
- gpm
- Double
-
- Water flow rate through the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_count``
- false
- #
- Integer
-
- Number of boreholes. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_length``
- false
- ft
- Double
-
- Average length of each borehole (vertical). Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_spacing``
- false
- ft
- Double
- "auto"
- Distance between bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_diameter``
- false
- in
- Double
- "auto"
- Diameter of bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_grout_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Grout type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Pipe type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_diameter``
- false
- in
- Choice
- "auto", "3/4" pipe", "1" pipe", "1-1/4" pipe"
- Pipe diameter of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``heating_system_has_flue_or_chimney``
- true
-
Expand Down Expand Up @@ -3912,6 +3984,66 @@ Arguments
- Choice
- "auto", "ACCA", "HERS", "MaxLoad"
- The auto-sizing methodology to use when the heat pump capacity is not provided. If not provided, the OS-HPXML default (see `HPXML HVAC Sizing Control <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-hvac-sizing-control>`_) is used.
* - ``geothermal_loop_configuration``
- false
-
- Choice
- "auto", "none", "vertical"
- Configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `Ground-to-Air Heat Pump <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#ground-to-air-heat-pump>`_) is used.
* - ``geothermal_loop_borefield_configuration``
- false
-
- Choice
- "auto", "Rectangle", "Open Rectangle", "C", "L", "U", "Lopsided U"
- Borefield configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_loop_flow``
- false
- gpm
- Double
-
- Water flow rate through the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_count``
- false
- #
- Integer
-
- Number of boreholes. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_length``
- false
- ft
- Double
-
- Average length of each borehole (vertical). Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_spacing``
- false
- ft
- Double
- "auto"
- Distance between bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_boreholes_diameter``
- false
- in
- Double
- "auto"
- Diameter of bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_grout_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Grout type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_type``
- false
-
- Choice
- "auto", "standard", "thermally enhanced"
- Pipe type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``geothermal_loop_pipe_diameter``
- false
- in
- Choice
- "auto", "3/4" pipe", "1" pipe", "1-1/4" pipe"
- Pipe diameter of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see `HPXML Geothermal Loops <https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops>`_) is used.
* - ``heating_system_has_flue_or_chimney``
- true
-
Expand Down
150 changes: 147 additions & 3 deletions measures/ResStockArguments/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -85,9 +85,22 @@ Presence of nearby buildings, trees, obstructions for infiltration model. If not

<br/>

**Site: Soil and Moisture Type**

Type of soil and moisture. This is used to inform ground conductivity and diffusivity. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site'>HPXML Site</a>) is used.

- **Name:** ``site_soil_and_moisture_type``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `clay, dry`, `clay, mixed`, `clay, wet`, `gravel, dry`, `gravel, mixed`, `gravel, wet`, `loam, dry`, `loam, mixed`, `loam, wet`, `sand, dry`, `sand, mixed`, `sand, wet`, `silt, dry`, `silt, mixed`, `silt, wet`, `unknown, dry`, `unknown, mixed`, `unknown, wet`

<br/>

**Site: Ground Conductivity**

Conductivity of the ground soil. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-site'>HPXML Site</a>) is used.
Conductivity of the ground soil. If provided, overrides the previous site and moisture type input.

- **Name:** ``site_ground_conductivity``
- **Type:** ``String``
Expand All @@ -96,6 +109,17 @@ Conductivity of the ground soil. If not provided, the OS-HPXML default (see <a h

<br/>

**Site: Ground Diffusivity**

Diffusivity of the ground soil. If provided, overrides the previous site and moisture type input.

- **Name:** ``site_ground_diffusivity``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Site: Zip Code**

Zip code of the home address.
Expand Down Expand Up @@ -1525,7 +1549,7 @@ The rated efficiency value of the cooling system. Ignored for evaporative cooler

**Cooling System: Cooling Compressor Type**

The compressor type of the cooling system. Only applies to central air conditioner. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner'>Central Air Conditioner</a>) is used.
The compressor type of the cooling system. Only applies to central air conditioner and mini-split. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#central-air-conditioner'>Central Air Conditioner</a>, <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-air-conditioner'>Mini-Split Air Conditioner</a>) is used.

- **Name:** ``cooling_system_cooling_compressor_type``
- **Type:** ``Choice``
Expand Down Expand Up @@ -1704,7 +1728,7 @@ The rated cooling efficiency value of the heat pump.

**Heat Pump: Cooling Compressor Type**

The compressor type of the heat pump. Only applies to air-to-air. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump'>Air-to-Air Heat Pump</a>) is used.
The compressor type of the heat pump. Only applies to air-to-air and mini-split. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#air-to-air-heat-pump'>Air-to-Air Heat Pump</a>, <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#mini-split-heat-pump'>Mini-Split Heat Pump</a>) is used.

- **Name:** ``heat_pump_cooling_compressor_type``
- **Type:** ``Choice``
Expand Down Expand Up @@ -1903,6 +1927,126 @@ Heat Pump crankcase heater power consumption in Watts. Applies only to air-to-ai

<br/>

**Geothermal Loop: Configuration**

Configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#ground-to-air-heat-pump'>Ground-to-Air Heat Pump</a>) is used.

- **Name:** ``geothermal_loop_configuration``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `none`, `vertical`

<br/>

**Geothermal Loop: Borefield Configuration**

Borefield configuration of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_borefield_configuration``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `Rectangle`, `Open Rectangle`, `C`, `L`, `U`, `Lopsided U`

<br/>

**Geothermal Loop: Loop Flow**

Water flow rate through the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_loop_flow``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Count**

Number of boreholes. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_count``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Length**

Average length of each borehole (vertical). Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML autosized default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_length``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Spacing**

Distance between bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_spacing``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Boreholes Diameter**

Diameter of bores. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_boreholes_diameter``
- **Type:** ``String``

- **Required:** ``false``

<br/>

**Geothermal Loop: Grout Type**

Grout type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_grout_type``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `standard`, `thermally enhanced`

<br/>

**Geothermal Loop: Pipe Type**

Pipe type of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_pipe_type``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `standard`, `thermally enhanced`

<br/>

**Geothermal Loop: Pipe Diameter**

Pipe diameter of the geothermal loop. Only applies to ground-to-air heat pump type. If not provided, the OS-HPXML default (see <a href='https://openstudio-hpxml.readthedocs.io/en/v1.7.0/workflow_inputs.html#hpxml-geothermal-loops'>HPXML Geothermal Loops</a>) is used.

- **Name:** ``geothermal_loop_pipe_diameter``
- **Type:** ``Choice``

- **Required:** ``false``

- **Choices:** `auto`, `3/4" pipe`, `1" pipe`, `1-1/4" pipe`

<br/>

**Heating System 2: Type**

The type of the second heating system.
Expand Down