Add GND connections to switchboxes #722

Open
wants to merge 2 commits into
base: master
Choose a base branch
from

Conversation

mkurc-ant
Copy link

@mkurc-ant mkurc-ant commented Dec 13, 2021

For PP3 switchboxes this PR adds treating of all incoming hop wires which seem to come from outside of the fabric as connected to GND (unless they are explicitly mapped to something according to the techfile).

@mkurc-ant
Copy link
Author

@lpawelcz This should solve at least some issues with decoding bitstreams from SpDE using fasm2bels.
@tpagarani Could you confirm that the implemented behavior actually reflects the hardware?

@tpagarani
Copy link

@lpawelcz This should solve at least some issues with decoding bitstreams from SpDE using fasm2bels. @tpagarani Could you confirm that the implemented behavior actually reflects the hardware?

@mkurc-ant, I think tech files provided by @lnsharma-ql should already have considered GND signals for unconnected wires. There should not be any need for implicit assumption. @lnsharma-ql , Could you please confirm?