Notifications
You must be signed in to change notification settings - Fork 485
Adding support for frient Intelligent Smoke Alarm (SMSZB-120) #2024
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
base: main
Are you sure you want to change the base?
Changes from 8 commits
0e0fdcc
812e12f
6918258
e3a3373
443a6b3
dc28c4d
788e991
a54d9c4
f2e3c21
1f57bf3
ec01237
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,50 @@ | ||
name: smoke-temp-battery-alarm | ||
components: | ||
- id: main | ||
capabilities: | ||
- id: smokeDetector | ||
version: 1 | ||
- id: temperatureMeasurement | ||
version: 1 | ||
- id: battery | ||
version: 1 | ||
- id: firmwareUpdate | ||
version: 1 | ||
- id: refresh | ||
version: 1 | ||
- id: alarm | ||
version: 1 | ||
config: | ||
values: | ||
- key: "alarm.value" | ||
enabledValues: | ||
- off | ||
- siren | ||
- key: "{{enumCommands}}" | ||
enabledValues: | ||
- off | ||
- siren | ||
categories: | ||
- name: SmokeDetector | ||
preferences: | ||
- preferenceId: tempOffset | ||
explicit: true | ||
- name: "tempSensitivity" | ||
title: "Temperature Sensitivity (18.0°)" | ||
description: "Minimum change in temperature to report" | ||
required: false | ||
preferenceType: number | ||
definition: | ||
minimum: 0.1 | ||
maximum: 2.0 | ||
default: 1.0 | ||
- name: "warningDuration" | ||
title: "Alarm duration (s)" | ||
description: "After how many seconds should the alarm turn off" | ||
required: false | ||
preferenceType: integer | ||
definition: | ||
minimum: 0 | ||
maximum: 65534 | ||
default: 240 | ||
|
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,4 +1,4 @@ | ||
-- Copyright 2022 SmartThings | ||
-- Copyright 2025 SmartThings | ||
-- | ||
-- Licensed under the Apache License, Version 2.0 (the "License"); | ||
-- you may not use this file except in compliance with the License. | ||
|
@@ -13,20 +13,205 @@ | |
-- limitations under the License. | ||
|
||
local battery_defaults = require "st.zigbee.defaults.battery_defaults" | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. leave this in place, thanks There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Fixed in the latest commit. |
||
local capabilities = require "st.capabilities" | ||
local zcl_clusters = require "st.zigbee.zcl.clusters" | ||
local zcl_global_commands = require "st.zigbee.zcl.global_commands" | ||
local data_types = require "st.zigbee.data_types" | ||
local alarm = capabilities.alarm | ||
local smokeDetector = capabilities.smokeDetector | ||
|
||
local is_frient_smoke_detector = function(opts, driver, device) | ||
if device:get_manufacturer() == "frient A/S" then | ||
return true | ||
local IASWD = zcl_clusters.IASWD | ||
local IASZone = zcl_clusters.IASZone | ||
local TemperatureMeasurement = zcl_clusters.TemperatureMeasurement | ||
|
||
local ALARM_COMMAND = "alarmCommand" | ||
local ALARM_LAST_DURATION = "Custom_Alarm_Duration" | ||
local ALARM_DEFAULT_MAX_DURATION = 0x00F0 | ||
local DEFAULT_WARNING_DURATION = 240 | ||
local BATTERY_MIN_VOLTAGE = 2.3 | ||
local BATTERY_MAX_VOLTAGE = 3.0 | ||
|
||
local TEMPERATURE_MEASUREMENT_ENDPOINT = 0x26 | ||
|
||
local alarm_command = { | ||
OFF = 0, | ||
SIREN = 1 | ||
} | ||
|
||
local CONFIGURATIONS = { | ||
{ | ||
cluster = IASZone.ID, | ||
attribute = IASZone.attributes.ZoneStatus.ID, | ||
minimum_interval = 30, | ||
maximum_interval = 300, | ||
data_type = IASZone.attributes.ZoneStatus.base_type, | ||
reportable_change = 1 | ||
}, | ||
{ | ||
cluster = TemperatureMeasurement.ID, | ||
attribute = TemperatureMeasurement.attributes.MeasuredValue.ID, | ||
minimum_interval = 60, | ||
maximum_interval = 600, | ||
data_type = TemperatureMeasurement.attributes.MeasuredValue.base_type, | ||
reportable_change = 100 | ||
} | ||
} | ||
|
||
local function device_added(driver, device) | ||
device:emit_event(alarm.alarm.off()) | ||
device:emit_event(smokeDetector.smoke.clear()) | ||
end | ||
|
||
local function device_init(driver, device) | ||
battery_defaults.build_linear_voltage_init(BATTERY_MIN_VOLTAGE, BATTERY_MAX_VOLTAGE)(driver, device) | ||
if CONFIGURATIONS ~= nil then | ||
for _, attribute in ipairs(CONFIGURATIONS) do | ||
device:add_configured_attribute(attribute) | ||
device:add_monitored_attribute(attribute) | ||
end | ||
end | ||
end | ||
|
||
local function do_configure(self, device) | ||
device:configure() | ||
device:send(IASWD.attributes.MaxDuration:write(device, ALARM_DEFAULT_MAX_DURATION)) | ||
end | ||
|
||
local info_changed = function (driver, device, event, args) | ||
for name, info in pairs(device.preferences) do | ||
if (device.preferences[name] ~= nil and args.old_st_store.preferences[name] ~= device.preferences[name]) then | ||
local input = device.preferences[name] | ||
if (name == "tempSensitivity") then | ||
local sensitivity = math.floor((device.preferences.tempSensitivity or 0.1)*100 + 0.5) | ||
device:send(TemperatureMeasurement.attributes.MeasuredValue:configure_reporting(device, 60, 600, sensitivity):to_endpoint(TEMPERATURE_MEASUREMENT_ENDPOINT)) | ||
elseif (name == "warningDuration") then | ||
device:set_field(ALARM_LAST_DURATION, input, {persist = true}) | ||
device:send(IASWD.attributes.MaxDuration:write(device, tonumber(input))) | ||
end | ||
end | ||
end | ||
return false | ||
end | ||
|
||
local frient_smoke_detector = { | ||
NAME = "Freint Smoke Detector", | ||
local function generate_event_from_zone_status(driver, device, zone_status, zigbee_message) | ||
print("Received ZoneStatus:", zone_status.value) | ||
|
||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. please remove this There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Fixed in latest release. |
||
if zone_status:is_test_set() then | ||
print("Test mode detected!") | ||
device:emit_event(smokeDetector.smoke.tested()) | ||
elseif zone_status:is_alarm1_set() then | ||
print("Smoke detected!") | ||
device:emit_event(smokeDetector.smoke.detected()) | ||
else | ||
device.thread:call_with_delay(6, function () | ||
print("Smoke cleared!") | ||
device:emit_event(smokeDetector.smoke.clear()) | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. same with these There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Fixed in latest release. |
||
end) | ||
end | ||
end | ||
|
||
local function ias_zone_status_attr_handler(driver, device, zone_status, zb_rx) | ||
generate_event_from_zone_status(driver, device, zone_status, zb_rx) | ||
end | ||
|
||
local function ias_zone_status_change_handler(driver, device, zb_rx) | ||
local zone_status = zb_rx.body.zcl_body.zone_status | ||
generate_event_from_zone_status(driver, device, zone_status, zb_rx) | ||
end | ||
|
||
local function send_siren_command(device) | ||
local warning_duration = device:get_field(ALARM_LAST_DURATION) or DEFAULT_WARNING_DURATION | ||
local sirenConfiguration = IASWD.types.SirenConfiguration(0x00) | ||
|
||
sirenConfiguration:set_warning_mode(0x01) | ||
|
||
device:send( | ||
IASWD.server.commands.StartWarning( | ||
device, | ||
sirenConfiguration, | ||
data_types.Uint16(warning_duration) | ||
) | ||
) | ||
|
||
end | ||
|
||
local emit_alarm_event = function(device, cmd) | ||
if cmd == alarm_command.OFF then | ||
device:emit_event(alarm.alarm.off()) | ||
else | ||
if cmd == alarm_command.SIREN then | ||
device:emit_event(alarm.alarm.siren()) | ||
end | ||
end | ||
end | ||
|
||
local default_response_handler = function(driver, device, zigbee_message) | ||
local command = zigbee_message.body.zcl_body.cmd.value | ||
local alarm_ev = device:get_field(ALARM_COMMAND) | ||
if command == IASWD.server.commands.StartWarning.ID then | ||
if alarm_ev ~= alarm_command.OFF then | ||
emit_alarm_event(device, alarm_ev) | ||
local lastDuration = device:get_field(ALARM_LAST_DURATION) or ALARM_DEFAULT_MAX_DURATION | ||
device.thread:call_with_delay(lastDuration, function(d) | ||
device:emit_event(alarm.alarm.off()) | ||
end) | ||
else | ||
emit_alarm_event(device,alarm_command.OFF) | ||
end | ||
end | ||
end | ||
|
||
local siren_alarm_siren_handler = function(driver, device, command) | ||
device:set_field(ALARM_COMMAND, alarm_command.SIREN, {persist = true}) | ||
send_siren_command(device) | ||
end | ||
|
||
|
||
local siren_switch_off_handler = function(driver, device, command) | ||
local sirenConfiguration = IASWD.types.SirenConfiguration(0x00) | ||
sirenConfiguration:set_warning_mode(0x00) | ||
device:set_field(ALARM_COMMAND, alarm_command.OFF, {persist = true}) | ||
|
||
device:send( | ||
IASWD.server.commands.StartWarning( | ||
device, | ||
sirenConfiguration | ||
) | ||
) | ||
end | ||
|
||
local frient_smoke_sensor = { | ||
NAME = "frient smoke sensor", | ||
lifecycle_handlers = { | ||
init = battery_defaults.build_linear_voltage_init(2.3, 3.0) | ||
added = device_added, | ||
doConfigure = do_configure, | ||
init = device_init, | ||
infoChanged = info_changed | ||
}, | ||
capability_handlers = { | ||
[alarm.ID] = { | ||
[alarm.commands.off.NAME] = siren_switch_off_handler, | ||
[alarm.commands.siren.NAME] = siren_alarm_siren_handler, | ||
}, | ||
}, | ||
zigbee_handlers = { | ||
global = { | ||
[IASWD.ID] = { | ||
[zcl_global_commands.DEFAULT_RESPONSE_ID] = default_response_handler | ||
}, | ||
}, | ||
cluster = { | ||
[IASZone.ID] = { | ||
[IASZone.client.commands.ZoneStatusChangeNotification.ID] = ias_zone_status_change_handler | ||
} | ||
}, | ||
attr = { | ||
[IASZone.ID] = { | ||
[IASZone.attributes.ZoneStatus.ID] = ias_zone_status_attr_handler | ||
} | ||
} | ||
}, | ||
can_handle = is_frient_smoke_detector | ||
can_handle = function(opts, driver, device, ...) | ||
return device:get_manufacturer() == "frient A/S" and device:get_model() == "SMSZB-120" | ||
end | ||
} | ||
|
||
return frient_smoke_detector | ||
return frient_smoke_sensor |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
please leave the copyright date as-is
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Fixed in latest release.