-
Notifications
You must be signed in to change notification settings - Fork 105
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Signed-off-by: SGudla <[email protected]>
- Loading branch information
1 parent
e0e8d1f
commit c5e48a1
Showing
2 changed files
with
194 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,193 @@ | ||
import argparse | ||
|
||
import pytest | ||
try: | ||
from adi.tools.adistream import run_adi_stream | ||
except: | ||
pytest.skip(allow_module_level=True) | ||
|
||
hardware = "ad5780" | ||
ref_neg = "-10" | ||
ref_pos = "+10" | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
@pytest.mark.parametrize("code_sel", ["0", "1"]) | ||
@pytest.mark.parametrize( | ||
"wave_types", ["sine", "cosine", "triangular", "square", "pwm"] | ||
) | ||
@pytest.mark.parametrize("v_lower_req, v_upper_req", [("-5", "5"), ("0", "10")]) | ||
@pytest.mark.parametrize("channel_order", ["asc", "desc"]) | ||
@pytest.mark.parametrize("output_freq", ["100", "500"]) | ||
def test_adistream_vaild_inputs( | ||
capsys, | ||
classname, | ||
iio_uri, | ||
code_sel, | ||
wave_types, | ||
v_lower_req, | ||
v_upper_req, | ||
channel_order, | ||
output_freq, | ||
): | ||
run_adi_stream( | ||
[ | ||
classname, | ||
iio_uri, | ||
ref_neg, | ||
ref_pos, | ||
"--output_freq", | ||
output_freq, | ||
"--code_sel", | ||
code_sel, | ||
"--wave_types", | ||
wave_types, | ||
"--v_lower_req", | ||
v_lower_req, | ||
"--v_upper_req", | ||
v_upper_req, | ||
"--channel_order", | ||
channel_order, | ||
], | ||
True, | ||
) | ||
captured = capsys.readouterr() | ||
assert ( | ||
captured.out == "Press escape key to stop cyclic data streaming..\n" | ||
"Data streaming started\n\r\n" | ||
"Data streaming finished\n" | ||
) | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("wave_types", ["pwm"]) | ||
@pytest.mark.parametrize("duty_cycle", ["10", "50", "75", "90"]) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
def test_adistream_dutycycle(capsys, classname, iio_uri, wave_types, duty_cycle): | ||
run_adi_stream( | ||
[ | ||
classname, | ||
iio_uri, | ||
ref_neg, | ||
ref_pos, | ||
"--wave_types", | ||
wave_types, | ||
"--duty_cycle", | ||
duty_cycle, | ||
], | ||
True, | ||
) | ||
captured = capsys.readouterr() | ||
assert ( | ||
captured.out == "Press escape key to stop cyclic data streaming..\n" | ||
"Data streaming started\n\r\n" | ||
"Data streaming finished\n" | ||
) | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("upper_req", ["15"]) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
def test_adistream_voltages_1(classname, iio_uri, upper_req): | ||
with pytest.raises(Exception) as context: | ||
run_adi_stream( | ||
[classname, iio_uri, ref_neg, ref_pos, "--v_upper_req", upper_req], True | ||
) | ||
|
||
assert ( | ||
str(context.value) | ||
== "required upper voltage cannot be greater than upper voltage reference" | ||
) | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("lower_req", ["-15"]) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
def test_adistream_voltages_2(classname, iio_uri, lower_req): | ||
with pytest.raises(Exception) as context: | ||
run_adi_stream( | ||
[classname, iio_uri, ref_neg, ref_pos, "--v_lower_req", lower_req], True | ||
) | ||
|
||
assert ( | ||
str(context.value) | ||
== "required lower voltage cannot be less than lower voltage reference" | ||
) | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("data_points", [("-10"), ("0")]) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
def test_adistream_datapoints(classname, iio_uri, data_points): | ||
with pytest.raises(argparse.ArgumentTypeError) as context: | ||
run_adi_stream( | ||
[ | ||
classname, | ||
iio_uri, | ||
ref_neg, | ||
ref_pos, | ||
"--data_points_per_wave", | ||
data_points, | ||
], | ||
True, | ||
) | ||
|
||
assert str(context.value) == "data points must be greater than 0" | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("classname", [("ad1234"), ("ad1123x")]) | ||
def test_adistream_invalid_classnames_1(classname, iio_uri): | ||
with pytest.raises(Exception) as context: | ||
run_adi_stream([classname, iio_uri, ref_neg, ref_pos], True) | ||
|
||
assert ( | ||
str(context.value) | ||
== f"The device {classname} is not supported. Supported devices are: " | ||
"ad578x,ad3552r,ad3530r,ad5754r,ad9152,ad9172\n" | ||
"Enable test_device (-t) flag to test devices not part of the supported " | ||
"devices list." | ||
) | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("classname", [("ad1234"), ("ad1123x")]) | ||
def test_adistream_invalid_classnames_2(classname, iio_uri): | ||
with pytest.raises(AttributeError) as context: | ||
run_adi_stream([classname, iio_uri, ref_neg, ref_pos, "--test_device"], True) | ||
|
||
assert str(context.value) == f"module 'adi' has no attribute '{classname}'" | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("output_freq", [("-10"), ("0")]) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
def test_adistream_output_freq(classname, iio_uri, output_freq): | ||
with pytest.raises(argparse.ArgumentTypeError) as context: | ||
run_adi_stream( | ||
[classname, iio_uri, ref_neg, ref_pos, "--output_freq", output_freq], True | ||
) | ||
|
||
assert str(context.value) == "output frequency required cannot be a negative number" | ||
|
||
|
||
######################################### | ||
@pytest.mark.iio_hardware(hardware, True) | ||
@pytest.mark.parametrize("duty_cycle", [("-10"), ("110")]) | ||
@pytest.mark.parametrize("classname", [("ad578x")]) | ||
def test_adistream_invalid_duty_cycle(classname, iio_uri, duty_cycle): | ||
with pytest.raises(argparse.ArgumentTypeError) as context: | ||
run_adi_stream( | ||
[classname, iio_uri, ref_neg, ref_pos, "--duty_cycle", duty_cycle], True | ||
) | ||
|
||
assert str(context.value) == "Duty cycle shall be in between 0 and 100" |