Original file line number Diff line number Diff line change
Expand Up @@ -15,7 +15,9 @@ Here below the example of setup of sensor and parameters to configure.
climate:
- platform: programmable_thermostat
name: room
heater: switch.riscaldamento
heater:
- switch.riscaldamento_1
- switch.riscaldamento_2
cooler: switch.condizionamento
actual_temp_sensor: sensor.target_temperature
min_temp: 10
Expand All @@ -30,12 +32,12 @@ Field | Value | Necessity | Comments
--- | --- | --- | ---
platform | `programmable_thermostat` | *Required* |
name| Programmable Thermostat | Optional |
heater | | *Conditional* | Switch that will activate/deactivate the heating system. At least one between `heater` and `cooler` has to be defined.
cooler | | *Conditional* | Switch that will activate/deactivate the cooling system. At least one between `heater` and `cooler` has to be defined.
heater | | *Conditional* | Switch that will activate/deactivate the heating system. This can be a single entity or a list of entities. At least one between `heater` and `cooler` has to be defined.
cooler | | *Conditional* | Switch that will activate/deactivate the cooling system. This can be a single entity or a list of entities. At least one between `heater` and `cooler` has to be defined.
actual_temp_sensor | | *Required* | Sensor of actual room temperature.
min_temp | 5 | Optional | Minimum temperature manually selectable.
max_temp | 40 | Optional | Maximum temperature manually selectable.
target_temp_sensor | | *Required* | Sensor that rapresent the desired temperature for the room. Suggestion: use my [`file_restore`][1] compontent or somthing similar.
target_temp_sensor | | *Required* | Sensor that rapresent the desired temperature for the room. Suggestion: use my [`file_restore`][1] compontent or something similar.
tolerance | 0.5 | Optional | Tolerance for turn on and off the switches mode.
initial_hvac_mode | `heat`, `cool`, `off` | Optional | If not set, components will restore old state after restart. I suggest to not use it.
related_climate | | Optional | To be used if the climate object is a slave of an other one. below 'Related climate' chapter a description.