Edit the "selectedFreqBands.txt" file for defining your frequency bands of interest and related parameters. See original README.md for more details about the GUI.
##Parameters:
- fName (String): frequency band name
- fStart (int): starting frequency bin
- fEnd (int): final frequency bin (note that its a bin number and not the frequency)
- Gain (float): multiplicative value of the average power
- Min (float): minimum value of the normalized power
- Max (float): maximum value of the normalized power
The final value (Gain*Power-Min)/(Max-Min) is sent by OSC to port 12000 at: /openbci/chan{channel number}/{frequency band name (i.e. fName)}
##Note:
- You can modify the Config file while the recording is running!!!
- Data acquisition is restarted every 10min. It's a temporary solution for encoutered unstable freeze of the recordings with the original GUI.
- a PureData patch for DMX manipulation
- an OSCulator patch to monitor ongoing values
- oscP5
- netP5
Guillaume Dumas, deep[at]introspection.eu