Skip to content

Commit

Permalink
Fixed OpenTherm commands codes
Browse files Browse the repository at this point in the history
  • Loading branch information
ihormelnyk committed Oct 22, 2018
1 parent de6be20 commit 2ceb49c
Show file tree
Hide file tree
Showing 2 changed files with 5 additions and 5 deletions.
2 changes: 1 addition & 1 deletion library.properties
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
name=OpenTherm Library
version=1.0.0
version=1.0.1
author=Ihor Melnyk <[email protected]>
maintainer=Ihor Melnyk <[email protected]>
sentence=OpenTherm Library for HVAC system control communication using Arduino and ESP8266 hardware.
Expand Down
8 changes: 4 additions & 4 deletions src/OpenTherm.h
Original file line number Diff line number Diff line change
Expand Up @@ -62,14 +62,14 @@ enum OpenThermMessageID {
TflowCH2, // f8.8 Flow water temperature CH2 circuit (°C)
Tdhw2, // f8.8 Domestic hot water temperature 2 (°C)
Texhaust, // s16 Boiler exhaust temperature (°C)
TdhwSetUBTdhwSetLB, // s8 / s8 DHW setpoint upper & lower bounds for adjustment (°C)
TdhwSetUBTdhwSetLB = 48, // s8 / s8 DHW setpoint upper & lower bounds for adjustment (°C)
MaxTSetUBMaxTSetLB, // s8 / s8 Max CH water setpoint upper & lower bounds for adjustment (°C)
HcratioUBHcratioLB, // s8 / s8 OTC heat curve ratio upper & lower bounds for adjustment
TdhwSet, // f8.8 DHW setpoint (°C) (Remote parameter 1)
TdhwSet = 56, // f8.8 DHW setpoint (°C) (Remote parameter 1)
MaxTSet, // f8.8 Max CH water setpoint (°C) (Remote parameters 2)
Hcratio, // f8.8 OTC heat curve ratio (°C) (Remote parameter 3)
RemoteOverrideFunction, // flag8 / - Function of manual and program changes in master and remote room setpoint.
OEMDiagnosticCode, // u16 OEM-specific diagnostic/service code
RemoteOverrideFunction = 100, // flag8 / - Function of manual and program changes in master and remote room setpoint.
OEMDiagnosticCode = 115, // u16 OEM-specific diagnostic/service code
BurnerStarts, // u16 Number of starts burner
CHPumpStarts, // u16 Number of starts CH pump
DHWPumpValveStarts, // u16 Number of starts DHW pump/valve
Expand Down

0 comments on commit 2ceb49c