Skip to content

Commit

Permalink
update docs
Browse files Browse the repository at this point in the history
  • Loading branch information
mcosovic committed Oct 15, 2024
1 parent 55befe3 commit 6678648
Show file tree
Hide file tree
Showing 2 changed files with 16 additions and 11 deletions.
2 changes: 1 addition & 1 deletion docs/src/manual/acOptimalPowerFlow.md
Original file line number Diff line number Diff line change
Expand Up @@ -508,7 +508,7 @@ print(system.bus.label, analysis.voltage.magnitude, analysis.voltage.angle)
##### Dual Variables
We also obtained all dual values. Here, we list only the dual variables for one type of constraint as an example:
```@repl ACOptimalPowerFlow
print(system.generator.label, analysis.method.dual.capability.active)
print(system.generator.label, analysis.method.dual.capability.reactive)
```
---

Expand Down
25 changes: 15 additions & 10 deletions docs/src/manual/dcOptimalPowerFlow.md
Original file line number Diff line number Diff line change
Expand Up @@ -12,11 +12,7 @@ To solve the DC optimal power flow problem and acquire generator active power ou
After obtaining the solution for DC optimal power flow, JuliaGrid offers a post-processing analysis function to compute powers associated with buses and branches:
* [`power!`](@ref power!(::PowerSystem, ::DCPowerFlow)).

Additionally, there are specialized functions dedicated to calculating specific types of active powers related to particular buses or branches:
* [`injectionPower`](@ref injectionPower(::PowerSystem, ::DCPowerFlow)),
* [`supplyPower`](@ref supplyPower(::PowerSystem, ::DCPowerFlow)),
* [`fromPower`](@ref fromPower(::PowerSystem, ::DCPowerFlow)),
* [`toPower`](@ref toPower(::PowerSystem, ::DCPowerFlow)).
Additionally, specialized functions are available for calculating specific types of [powers](@ref DCPowerAnalysisAPI) for individual buses, branches, or generators.

---

Expand Down Expand Up @@ -75,8 +71,17 @@ fieldnames(typeof(analysis.method.variable))

---

##### Variable Names
Users have the option to define custom variable names for printing and writing equations, which can help present them in a more compact form. For example:
```@example DCOptimalPowerFlow
analysis = dcOptimalPowerFlow(system, HiGHS.Optimizer; active = "P", angle = "θ")
nothing # hide
```

---

##### Add Variables
The user has the ability to easily add new variables to the defined DC optimal power flow model by using the [`@variable`](https://jump.dev/JuMP.jl/stable/api/JuMP/#JuMP.@variable) macro from the JuMP package. Here is an example:
The user has the ability to easily add new variables to the defined DC optimal power flow model by using the [`@variable`](https://jump.dev/JuMP.jl/stable/api/JuMP/#JuMP.@variable) macro from the JuMP package:
```@example DCOptimalPowerFlow
JuMP.@variable(analysis.method.jump, newVariable)
nothing # hide
Expand Down Expand Up @@ -328,8 +333,8 @@ solve!(system, flow)

After obtaining the solution, we can calculate the active power outputs of the generators and utilize the bus voltage angles to set the starting values. In this case, the `generator` and `voltage` fields of the `DCOptimalPowerFlow` type can be employed to store the new starting values:
```@example DCOptimalPowerFlow
for (key, value) in system.generator.label
analysis.power.generator.active[value] = generatorPower(system, flow; label = key)
for (key, idx) in system.generator.label
analysis.power.generator.active[idx] = generatorPower(system, flow; label = key)
end
for i = 1:system.bus.number
Expand Down Expand Up @@ -381,7 +386,7 @@ analysis.method.dual.balance.active[1]
---

##### Print Results in the REPL
Users can utilize the functions [`printBusData`](@ref printBusData) and [`printGeneratorData`](@ref printGeneratorData) to display results. Additionally, to print bus, branch, or generator-related constraint data with the desired units, users can utilize any of the functions provided in the [Print Constraint Data](@ref PrintConstraintDataAPI) section. For example:
Users can utilize the functions [`printBusData`](@ref printBusData) and [`printGeneratorData`](@ref printGeneratorData) to display results. Additionally, the functions listed in the [Print Constraint Data](@ref PrintConstraintDataAPI) section allow users to print constraint data related to buses, branches, or generators in the desired units. For example:
```@example DCOptimalPowerFlow
@power(MW, MVAr, pu)
printBusConstraint(system, analysis)
Expand Down Expand Up @@ -435,7 +440,7 @@ print(system.bus.label, analysis.voltage.angle)
##### Dual Variables
We also obtained all dual values. Here, we list only the dual variables for one type of constraint as an example:
```@repl DCOptimalPowerFlow
print(system.generator.label, analysis.method.dual.capability.active)
print(system.branch.label, analysis.method.dual.flow.active)
```

---
Expand Down

0 comments on commit 6678648