Use smaller Int types where possible #33

Merged
merged 2 commits into from
Oct 23, 2021
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
99 changes: 52 additions & 47 deletions src/types.jl
Original file line number Diff line number Diff line change
Expand Up @@ -19,7 +19,7 @@ struct CaseID <: Tables.AbstractRow
0 - base case (i.e., clear the working case before adding data to it).
1 - add data to the working case.
"""
ic::Int
ic::Int8
"System base MVA."
sbase::Float64
end
Expand Down Expand Up @@ -48,6 +48,11 @@ Tables.rowcount(x::Records) = length(x) # faster than going via `columnnames`
Base.length(x::Records) = length(getfield(x, 1)::Vector)
Base.size(x::R) where {R <: Records} = (length(x), fieldcount(R))

const BusNum = Int32
const AreaNum = Int16
const ZoneNum = Int16
const OwnerNum = Int16

"""
$TYPEDEF
Expand All @@ -63,7 +68,7 @@ $TYPEDFIELDS
"""
struct Buses <: Records
"Bus number (1 to 999997)."
i::Vector{Int}
i::Vector{BusNum}
"""
Alphanumeric identifier assigned to bus "I".
The name may be up to twelve characters and must be enclosed in single quotes.
Expand All @@ -81,7 +86,7 @@ struct Buses <: Records
It has no power or reactive limits and regulates voltage at a fixed reference angle.
4 - disconnected or isolated bus.
"""
ide::Vector{Int}
ide::Vector{Int8} # 1, 2, 3 or 4
"""
Active component of shunt admittance to ground; entered in MW at one per unit voltage.
GL should not include any resistive admittance load, which is entered as part of load data.
Expand All @@ -96,15 +101,15 @@ struct Buses <: Records
"""
bl::Vector{Float64}
"Area number. 1 through the maximum number of areas at the current size level."
area::Vector{Int}
area::Vector{AreaNum}
"Zone number. 1 through the maximum number of zones at the current size level."
zone::Vector{Int}
zone::Vector{ZoneNum}
"Bus voltage magnitude; entered in pu."
vm::Vector{Float64}
"Bus voltage phase angle; entered in degrees."
va::Vector{Float64}
"Owner number. 1 through the maximum number of owners at the current size level."
owner::Vector{Int}
owner::Vector{OwnerNum}
end

"""
Expand All @@ -120,7 +125,7 @@ $TYPEDFIELDS
"""
struct Loads <: Records
"Buses number, or extended buses name enclosed in single quotes."
i::Vector{Int}
i::Vector{BusNum}
"""
One- or two-character uppercase non blank alphanumeric load identifier used to distinguish among multiple loads at bus "I".
It is recommended that, at buses for which a single load is present, the load be designated as having the load identifier '1'.
Expand All @@ -129,9 +134,9 @@ struct Loads <: Records
"Initial load status of one for in-service and zero for out-of-service."
status::Vector{Bool}
"Area to which the load is assigned (1 through the maximum number of areas at the current size level)."
area::Vector{Int}
area::Vector{AreaNum}
"Zone to which the load is assigned (1 through the maximum number of zones at the current size level)."
zone::Vector{Float64}
zone::Vector{ZoneNum}
"Active power component of constant MVA load; entered in MW."
pl::Vector{Float64}
"Reactive power component of constant MVA load; entered in Mvar."
Expand All @@ -148,7 +153,7 @@ struct Loads <: Records
"""
yq::Vector{Float64}
"Owner to which the load is assigned (1 through the maximum number of owners at the current size level)."
owner::Vector{Int}
owner::Vector{OwnerNum}
end


Expand All @@ -164,7 +169,7 @@ $TYPEDFIELDS
"""
struct Generators <: Records
"Bus number, or extended bus name enclosed in single quotes."
i::Vector{Int}
i::Vector{BusNum}
"""
One- or two-character uppercase non blank alphanumeric machine identifier used to distinguish among multiple machines at bus "I".
It is recommended that, at buses for which a single machine is present, the machine be designated as having the machine identifier ’1’.
Expand Down Expand Up @@ -200,7 +205,7 @@ struct Generators <: Records
IREG is entered as zero if the plant is to regulate its own voltage and must be zero for a type three (swing) bus.
IREG = 0 by default.
"""
ireg::Vector{Int}
ireg::Vector{BusNum}
"""
Total MVA base of the units represented by this machine; entered in MVA.
This quantity is not needed in normal power flow and equivalent construction work,
Expand Down Expand Up @@ -257,7 +262,7 @@ struct Generators <: Records
Each machine may have up to four owners.
By default, O1 is the owner to which bus "I" is assigned and O2, O3, and O4 are zero.
"""
oi::Vector{Int}
oi::Vector{OwnerNum}
"""
Fraction of total ownership assigned to owner Oi; each Fi must be positive.
The Fi values are normalized such that they sum to 1.0 before they are placed in the working case.
Expand Down Expand Up @@ -287,13 +292,13 @@ $TYPEDFIELDS
"""
struct Branches <: Records
"Branch \"from bus\" number, or extended bus name enclosed in single quotes."
i::Vector{Int}
i::Vector{BusNum}
"""
Branch "to bus" number, or extended bus name enclosed in single quotes.
"J" is entered as a negative number, or with a minus sign before the first character of the extended bus name,
to designate it as the metered end; otherwise, bus "I" is assumed to be the metered end.
"""
j::Vector{Int}
j::Vector{BusNum}
"""
One- or two-character uppercase nonblank alphanumeric branch circuit identifier;
the first character of CKT must not be an ampersand "&".
Expand Down Expand Up @@ -357,7 +362,7 @@ struct Branches <: Records
Each branch may have up to four owners.
By default, O1 is the owner to which bus "I" is assigned and O2, O3, and O4 are zero.
"""
oi::Vector{Int}
oi::Vector{OwnerNum}
"""
Fraction of total ownership assigned to owner Oi; each Fi must be positive.
The Fi values are normalized such that they sum to 1.0 before they are placed in the working case.
Expand Down Expand Up @@ -399,19 +404,19 @@ struct Transformers <: Records
phase shift angle may be adjusted by the power flow solution activities;
any winding(s) of a three-winding transformer may be adjusted. No default is allowed.
"""
i::Vector{Int}
i::Vector{BusNum}
"""
The bus number, or extended bus name enclosed in single quotes, of the bus to which the
second winding is connected. This winding may have a fixed, off-nominal tap ratio
assigned to it. No default is allowed.
"""
j::Vector{Int}
j::Vector{BusNum}
"""
The bus number, or extended bus name enclosed in single quotes, of the bus to which the
third winding is connected. Zero is used to indicate that no third winding is present.
_Always equal to zero for a two-winding transformer._
"""
k::Vector{Int}
k::Vector{BusNum}
"""
One- or two-character uppercase nonblank alphanumeric transformer circuit identifier;
the first character of `ckt` must not be an ampersand ('&').
Expand All @@ -425,7 +430,7 @@ struct Transformers <: Records
* 2 for winding voltage in kV.
`cw` = 1 by default.
"""
cw::Vector{Int} # 1 or 2
cw::Vector{Int8} # 1 or 2
"""
The impedance data I/O code that defines the units in which the winding impedances
`r1_2` and `x1_2` are specified:
Expand All @@ -435,15 +440,15 @@ struct Transformers <: Records
and winding bus base voltage.
`cz` = 1 by default.
"""
cz::Vector{Int} # 1, 2 or 3
cz::Vector{Int8} # 1, 2 or 3
"""
The magnetizing admittance I/O code that defines the units in which `mag1` and `mag2` are specified:
* 1 for complex admittance in pu on system base quantities;
* 2 for no load loss in watts and exciting current in pu on winding one to two base MVA
and nominal voltage.
`cm` = 1 by default.
"""
cm::Vector{Int} # 1 or 2
cm::Vector{Int8} # 1 or 2
"""
When `cm` is 1, `mag1` is the magnetizing conductance in pu on system base quantities;
when `cm` is 2, `mag1` is the no load loss in watts.
Expand All @@ -463,7 +468,7 @@ struct Transformers <: Records
* 2 (for the winding two bus).
`nmetr` = 2 by default.
"""
nmetr::Vector{Int} # 1 or 2
nmetr::Vector{Int8} # 1 or 2
"""
An alphanumeric identifier assigned to the transformer. The name may be up to twelve characters.
`name` may contain any combination of blanks, uppercase letters, numbers and special characters.
Expand All @@ -479,7 +484,7 @@ struct Transformers <: Records
An owner number; (1 through the maximum number of owners at the current size level).
Each transformer may have up to four owners. By default, O1 is the owner to which bus "I" is assigned
"""
oi::Vector{Int}
oi::Vector{OwnerNum}
"""
The fraction of total ownership assigned to owner `Oi`; each Fi must be positive.
The Fi values are normalized such that they sum to 1.0 before they are placed in the working case.
Expand Down Expand Up @@ -624,7 +629,7 @@ struct Transformers <: Records
a negative control mode suppresses the automatic adjustment of this transformer winding.
`cod1` = 0 by default.
"""
cod1::Vector{Int}
cod1::Vector{Int8} # one of: -4, -3, -2, -1, 0, 1, 2, 3, 4
"""
The bus number, or extended bus name enclosed in single quotes, of the bus whose voltage
is to be controlled by the transformer turns ratio adjustment option of the power flow
Expand All @@ -638,7 +643,7 @@ struct Transformers <: Records
if `cont1` is entered as a negative number, the ratio is adjusted as if bus `|cont1|` is on the winding one side of the transformer.
`cont1` = 0 by default.
"""
cont1::Vector{Int}
cont1::Vector{BusNum}
"""
`rma1` is the upper limit (and `rmi1` the lower limit) of either:
* Off-nominal turns ratio in pu of winding one bus base voltage when `|cod1|` is 1 or 2 and `cw` is 1;
Expand Down Expand Up @@ -666,7 +671,7 @@ struct Transformers <: Records
`ntp1` must be between 2 and 9999.
`ntp1` = 33 by default.
"""
ntp1::Vector{Int}
ntp1::Vector{Int16}
"""
The number of a transformer impedance correction table if this transformer winding’s
impedance is to be a function of either off-nominal turns ratio or phase shift angle,
Expand Down Expand Up @@ -736,7 +741,7 @@ struct Transformers <: Records
`cod2` = 0 by default.
_Ignored for a two-winding transformer._
"""
cod2::Vector{Union{Int, Missing}} # one of: -3, -2, -1, 0, 1, 2, 3
cod2::Vector{Union{Int8, Missing}} # one of: -3, -2, -1, 0, 1, 2, 3
"""
The bus number, or extended bus name enclosed in single quotes, of the bus whose voltage
is to be controlled by the transformer turns ratio adjustment option of the power flow
Expand All @@ -752,7 +757,7 @@ struct Transformers <: Records
two side of the transformer. `cont2` = 0 by default.
_Ignored for a two-winding transformer._
"""
cont2::Vector{Union{Int, Missing}}
cont2::Vector{Union{BusNum, Missing}}
"""
`rma2` is the upper limit (and `rmi2` the lower limit) of either:
* Off-nominal turns ratio in pu of winding two bus base voltage when `|cod2|` is 1 or 2 and `cw` is 1;
Expand Down Expand Up @@ -792,7 +797,7 @@ struct Transformers <: Records
`ntp2` = 33 by default.
_Ignored for a two-winding transformer._
"""
ntp2::Vector{Union{Int, Missing}}
ntp2::Vector{Union{Int16, Missing}}
"""
The number of a transformer impedance correction table if this transformer winding’s
impedance is to be a function of either off-nominal turns ratio or phase shift angle,
Expand Down Expand Up @@ -868,7 +873,7 @@ struct Transformers <: Records
`cod3` = 0 by default.
_Ignored for a two-winding transformer._
"""
cod3::Vector{Union{Int, Missing}}
cod3::Vector{Union{Int8, Missing}} # one of: -3, -2, -1, 0, 1, 2, 3
"""
The bus number, or extended bus name enclosed in single quotes, of the bus whose voltage
is to be controlled by the transformer turns ratio adjustment option of the power flow
Expand All @@ -884,7 +889,7 @@ struct Transformers <: Records
three side of the transformer. `cont3` = 0 by default.
_Ignored for a two-winding transformer._
"""
cont3::Vector{Union{Int, Missing}}
cont3::Vector{Union{BusNum, Missing}}
"""
`rma3` is the upper limit (and `rmi3` the lower limit) of either:
* Off-nominal turns ratio in pu of winding three bus base voltage when `|cod3|` is 1 or 2 and `cw` is 1;
Expand Down Expand Up @@ -924,7 +929,7 @@ struct Transformers <: Records
`ntp3` = 33 by default.
_Ignored for a two-winding transformer._
"""
ntp3::Vector{Union{Int, Missing}}
ntp3::Vector{Union{Int16, Missing}}
"""
The number of a transformer impedance correction table if this transformer winding’s
impedance is to be a function of either off-nominal turns ratio or phase shift angle,
Expand Down Expand Up @@ -1017,15 +1022,15 @@ struct AreaInterchanges <: Records
"""
Area number (1 through the maximum number of areas at the current size level)
"""
i::Vector{Int}
i::Vector{AreaNum}
"""
Bus number, or extended bus name enclosed in single quotes, of the area slack bus for
area interchange control. The bus must be a generator (type two) bus in the specified
area. Any area containing a system swing bus (type three) must have either that swing
bus or a bus number of zero specified for its area slack bus number.
`isw` = 0 by default.
"""
isw::Vector{Int}
isw::Vector{BusNum}
"""
Desired net interchange leaving the area (export); entered in MW.
`pdes` = 0.0 by default.
Expand Down Expand Up @@ -1072,7 +1077,7 @@ struct TwoTerminalDCLines <: Records
"""
The DC line number.
"""
i::Vector{Int}
i::Vector{Int32}
"""
Control mode:
* 0 for blocked,
Expand Down Expand Up @@ -1139,7 +1144,7 @@ struct TwoTerminalDCLines <: Records
Iteration limit for capacitor commutated two-terminal DC line Newton solution procedure.
`cccitmx` = 20 by default.
"""
cccitmx::Vector{Int}
cccitmx::Vector{Int32}
"""
Acceleration factor for capacitor commutated two-terminal DC line Newton solution procedure.
`cccacc` = 1.0 by default.
Expand All @@ -1150,12 +1155,12 @@ struct TwoTerminalDCLines <: Records
Rectifier converter bus number, or extended bus name enclosed in single quotes.
No default.
"""
ipr::Vector{Int}
ipr::Vector{BusNum}
"""
Number of bridges in series (rectifier).
No default.
"""
nbr::Vector{Int}
nbr::Vector{Int32}
"""
Nominal maximum rectifier firing angle; entered in degrees.
No default.
Expand Down Expand Up @@ -1212,19 +1217,19 @@ struct TwoTerminalDCLines <: Records
between the phase angles at this bus and the AC/DC interface (i.e. the converter bus, `ipr`).
`icr` = 0 by default.
"""
icr::Vector{Int}
icr::Vector{BusNum}
"""
Winding one side "from bus" number, or extended bus name enclosed in single quotes,
of a two-winding transformer.
`ifr` = 0 by default.
"""
ifr::Vector{Int}
ifr::Vector{BusNum}
"""
Winding two side "to bus" number, or extended bus name enclosed in single quotes,
of a two-winding transformer.
`itr` = 0 by default.
"""
itr::Vector{Int}
itr::Vector{BusNum}
"""
Circuit identifier; the branch described by `ifr`, `itr`, and `idr` must have been entered
as a two-winding transformer; an AC transformer may control at most only one DC converter.
Expand All @@ -1248,11 +1253,11 @@ struct TwoTerminalDCLines <: Records
"""
Inverter converter bus number, or extended bus name enclosed in single quotes.
"""
ipi::Vector{Int}
ipi::Vector{BusNum}
"""
Number of bridges in series (inverter).
"""
nbi::Vector{Int}
nbi::Vector{Int32}
"""
Nominal maximum inverter firing angle; entered in degrees.
"""
Expand Down Expand Up @@ -1296,17 +1301,17 @@ struct TwoTerminalDCLines <: Records
"""
Inverter firing angle measuring bus number, or extended bus name enclosed in single quotes.
"""
ici::Vector{Int}
ici::Vector{BusNum}
"""
Winding one side "from bus" number, or extended bus name enclosed in single quotes,
of a two-winding transformer.
"""
ifi::Vector{Int}
ifi::Vector{BusNum}
"""
Winding two side "to bus" number, or extended bus name enclosed in single quotes,
of a two-winding transformer.
"""
iti::Vector{Int}
iti::Vector{BusNum}
"""
Circuit identifier; the branch described by `ifr`, `itr`, and `idr` must have been entered
as a two-winding transformer; an AC transformer may control at most only one DC converter.
Expand Down