Skip to content

Building indicators

Bocher edited this page Feb 28, 2022 · 2 revisions

The table building_indicators contains the initial informations being in the input table 'building' (id_build, id_source, height_wall, height_roof, etc. - cf. building input table), the identifier of the block and of the RSU it belongs to (id_rsu, id_block) and a certain number of indicators described below.

AREA

Description: Building's area.

Method: Area of the building footprint

AREA_CONCAVITY

Description: Calculates a degree of convexity of a building (according to the building surface).

Method: Area / Convex Hull area

Range of values: [0, 1] - the closer the result from 1, the more convex the building.

COMMON_WALL_FRACTION

Description: Fraction of linear of facade (also called “party walls”) shared with other buildings.

Method: Shared facade length / total facade length

CONTIGUITY

Description: Fraction of wall shared with other buildings

Method: Shared wall area / total wall area

FLOOR_AREA

Description: Building's floor area.

Method: Area * Number of level

FORM_FACTOR

Description: Ratio between the building’s area and the square of the external building’s perimeter

Method: Area / (perimeter)^2

LIKELIHOOD_LARGE_BUILDING

Description: Building closeness to a 50 m wide isolated building (where NUMBER_BUILDING_NEIGHBOR = 0).

Method: The step 9 of the decision tree used for the MaPUCE project manual building typology classification consists of checking whether a building has a horizontal extent larger than 50 m. We therefore introduce an indicator which measures the horizontal extent of buildings. This indicator is based on the largest side of the building minimum rectangle. We then use a logistic function to avoid threshold effects (e.g. totally different result for building sizes of 49 m and 51 m). The gamma and x0 parameters in the logistic function are specified after analysis of the training data to identify the real size of the buildings classified as larger than 50 m in the subjective training process.

MINIMUM_BUILDING_SPACING

Description: Building closest distance (expressed in meter) to an other building.

Method: Min(distance(building, other buildings within bufferDist)) , where the buffer size of search is defined in the bufferDist parameter (default value = 100 m)

Warning:

  • If the building touches an other building, the result is 0.
  • If there is no building in a 100m circle around the building, the result is set to 100m (this value may be different if the bufferDist default value is modified).

NUMBER_BUILDING_NEIGHBOR

Description: Number of neighboring buildings, in contact with the building.

Method: Count the number of buildings touching (at least one point) the building of interest.

PERIMETER

Description: Building's perimeter (external perimeter, do not consider courtyard).

Method: External building perimeter

PERIMETER_CONVEXITY

Description: Calculates a degree of convexity of a building (according to the building perimeter).

Method: Convex Hull perimeter / Perimeter

Range of values: [0, 1] - the closer the result from 1, the more convex the building.

RAW_COMPACTNESS

Description: Ratio between building external surfaces (walls and roof) and the building volume at the power 2/3.

Method: (External walls area + courtyard walls area + roof area) / (volume^(2/3))

Warning: For the calculation, the roof is supposed to have a gable and the roof surface is calculated considering that the building is square (otherwise, the choice related to the gable direction - which is not known - would affect the result).

ROAD_DISTANCE

Description: Building closest distance (expressed in meter) to a road,

Method: The search is made within a buffer area around the building whose size is defined in the bufferDist parameter (default value = 100 m).

Min(distance(building, roads within bufferDist))

Warning:

  • If the building touches a road, the result is 0.
  • If the roads are further than 100m from the building, the result is set to 100m (this value may be different if the bufferDist default value is modified).

TOTAL_FACADE_LENGTH

Description: Total length of external facade.

Method: Building perimeter + Courtyard perimeter

VOLUME

Description: Building's volume.

Method: The building volume is calculated considering that all buildings have either horizontal or gable roofs. In this case, the building volume can be calculated using the following equation:

Area * ((Wall height + Roof height)/2)

POP

Description: Number of people according the building's floor area.

Method: This indicator estimates the number of people using a census count population table currently extracted from the https://www.worldpop.org website. It uses a gridded population layer at 100 meters resolution. The population is only estimated for the types building and residential.