Fix java per unit (#744)
Browse files Browse the repository at this point in the history
Signed-off-by: Etienne LESOT <[email protected]>
(cherry picked from commit aad85d7)
  • Loading branch information
EtienneLt authored and HugoKulesza committed May 21, 2024
1 parent de15ee6 commit 8bcc3ea
Show file tree
Hide file tree
Showing 3 changed files with 37 additions and 13 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -259,8 +259,8 @@ static NetworkDataframeMapper generators() {
.doubles("max_q_at_p", getPerUnitMaxQ(getOppositeP()), false)
.doubles("rated_s", (g, context) -> g.getRatedS(), (g, ratedS, context) -> g.setRatedS(ratedS))
.strings("reactive_limits_kind", NetworkDataframes::getReactiveLimitsKind)
.doubles("target_v", (g, context) -> perUnitV(context, g.getTargetV(), g.getRegulatingTerminal()),
(g, v, context) -> g.setTargetV(unPerUnitV(context, v, g.getRegulatingTerminal())))
.doubles("target_v", (g, context) -> perUnitTargetV(context, g.getTargetV(), g.getRegulatingTerminal(), g.getTerminal()),
(g, v, context) -> g.setTargetV(unPerUnitTargetV(context, v, g.getRegulatingTerminal(), g.getTerminal())))
.doubles("target_q", (g, context) -> perUnitPQ(context, g.getTargetQ()), (g, q, context) -> g.setTargetQ(unPerUnitPQ(context, q)))
.booleans("voltage_regulator_on", Generator::isVoltageRegulatorOn, Generator::setVoltageRegulatorOn)
.strings("regulated_element_id", generator -> NetworkUtil.getRegulatedElementId(generator::getRegulatingTerminal),
Expand Down Expand Up @@ -357,8 +357,8 @@ static NetworkDataframeMapper shunts() {
.ints("max_section_count", ShuntCompensator::getMaximumSectionCount)
.ints("section_count", ShuntCompensator::getSectionCount, ShuntCompensator::setSectionCount)
.booleans("voltage_regulation_on", ShuntCompensator::isVoltageRegulatorOn, ShuntCompensator::setVoltageRegulatorOn)
.doubles("target_v", (sc, context) -> perUnitV(context, sc.getTargetV(), sc.getRegulatingTerminal()),
(sc, v, context) -> sc.setTargetV(unPerUnitV(context, v, sc.getRegulatingTerminal())))
.doubles("target_v", (sc, context) -> perUnitTargetV(context, sc.getTargetV(), sc.getRegulatingTerminal(), sc.getTerminal()),
(sc, v, context) -> sc.setTargetV(unPerUnitTargetV(context, v, sc.getRegulatingTerminal(), sc.getTerminal())))
.doubles("target_deadband", (sc, context) -> perUnitV(context, sc.getTargetDeadband(), sc.getRegulatingTerminal()),
(sc, tb, context) -> sc.setTargetDeadband(unPerUnitV(context, tb, sc.getRegulatingTerminal())))
.strings("regulating_bus_id", sc -> getBusId(sc.getRegulatingTerminal()))
Expand Down Expand Up @@ -633,8 +633,8 @@ static NetworkDataframeMapper vscs() {
.doubles("min_q_at_p", getPerUnitMinQ(getOppositeP()), false)
.doubles("max_q_at_p", getPerUnitMaxQ(getOppositeP()), false)
.strings("reactive_limits_kind", NetworkDataframes::getReactiveLimitsKind)
.doubles("target_v", (vsc, context) -> perUnitV(context, vsc.getVoltageSetpoint(), vsc.getRegulatingTerminal()),
(vsc, targetV, context) -> vsc.setVoltageSetpoint(unPerUnitV(context, targetV, vsc.getRegulatingTerminal())))
.doubles("target_v", (vsc, context) -> perUnitTargetV(context, vsc.getVoltageSetpoint(), vsc.getRegulatingTerminal(), vsc.getTerminal()),
(vsc, targetV, context) -> vsc.setVoltageSetpoint(unPerUnitTargetV(context, targetV, vsc.getRegulatingTerminal(), vsc.getTerminal())))
.doubles("target_q", (vsc, context) -> perUnitPQ(context, vsc.getReactivePowerSetpoint()),
(vsc, targetQ, context) -> vsc.setReactivePowerSetpoint(unPerUnitPQ(context, targetQ)))
.booleans("voltage_regulator_on", VscConverterStation::isVoltageRegulatorOn, VscConverterStation::setVoltageRegulatorOn)
Expand All @@ -659,8 +659,8 @@ private static NetworkDataframeMapper svcs() {
.strings("name", svc -> svc.getOptionalName().orElse(""))
.doubles("b_min", (svc, context) -> svc.getBmin(), (svc, bMin, context) -> svc.setBmin(bMin))
.doubles("b_max", (svc, context) -> svc.getBmax(), (svc, bMax, context) -> svc.setBmax(bMax))
.doubles("target_v", (svc, context) -> perUnitV(context, svc.getVoltageSetpoint(), svc.getRegulatingTerminal()),
(svc, targetV, context) -> svc.setVoltageSetpoint(unPerUnitV(context, targetV, svc.getRegulatingTerminal())))
.doubles("target_v", (svc, context) -> perUnitTargetV(context, svc.getVoltageSetpoint(), svc.getRegulatingTerminal(), svc.getTerminal()),
(svc, targetV, context) -> svc.setVoltageSetpoint(unPerUnitTargetV(context, targetV, svc.getRegulatingTerminal(), svc.getTerminal())))
.doubles("target_q", (svc, context) -> perUnitPQ(context, svc.getReactivePowerSetpoint()),
(svc, targetQ, context) -> svc.setReactivePowerSetpoint(unPerUnitPQ(context, targetQ)))
.enums("regulation_mode", StaticVarCompensator.RegulationMode.class,
Expand Down Expand Up @@ -867,8 +867,8 @@ private static NetworkDataframeMapper rtcs() {
.ints("step_count", t -> t.getRatioTapChanger().getStepCount())
.booleans("on_load", t -> t.getRatioTapChanger().hasLoadTapChangingCapabilities(), (t, v) -> t.getRatioTapChanger().setLoadTapChangingCapabilities(v))
.booleans("regulating", t -> t.getRatioTapChanger().isRegulating(), (t, v) -> t.getRatioTapChanger().setRegulating(v))
.doubles("target_v", (t, context) -> perUnitV(context, t.getRatioTapChanger().getTargetV(), t.getRatioTapChanger().getRegulationTerminal()),
(t, v, context) -> t.getRatioTapChanger().setTargetV(unPerUnitV(context, v, t.getRatioTapChanger().getRegulationTerminal())))
.doubles("target_v", (t, context) -> perUnitTargetV(context, t.getRatioTapChanger().getTargetV(), t.getRatioTapChanger().getRegulationTerminal(), t.getTerminal2()),
(t, v, context) -> t.getRatioTapChanger().setTargetV(unPerUnitTargetV(context, v, t.getRatioTapChanger().getRegulationTerminal(), t.getTerminal2())))
.doubles("target_deadband", (t, context) -> t.getRatioTapChanger().getTargetDeadband(),
(t, v, context) -> t.getRatioTapChanger().setTargetDeadband(v))
.strings("regulating_bus_id", t -> getBusId(t.getRatioTapChanger().getRegulationTerminal()))
Expand Down
28 changes: 26 additions & 2 deletions java/src/main/java/com/powsybl/dataframe/network/PerUnitUtil.java
Original file line number Diff line number Diff line change
Expand Up @@ -212,9 +212,21 @@ public static double unPerUnitV(DataframeContext dataframeContext, double v, Bus
return unPerUnitV(dataframeContext, v, bus.getVoltageLevel().getNominalV());
}

public static double unPerUnitTargetV(DataframeContext dataframeContext, double v, Terminal distantTerminal, Terminal localTerminal) {
if (distantTerminal != null) {
return unPerUnitV(dataframeContext, v, distantTerminal);
} else {
return unPerUnitV(dataframeContext, v, localTerminal);
}
}

public static double unPerUnitV(DataframeContext dataframeContext, double v, Terminal terminal) {
if (terminal == null) {
throw new PowsyblException("terminal not found for un per unit V");
if (dataframeContext.isPerUnit()) {
throw new PowsyblException("terminal not found for un per unit V");
} else {
return v;
}
}
return unPerUnitV(dataframeContext, v, terminal.getVoltageLevel().getNominalV());
}
Expand All @@ -231,9 +243,21 @@ public static double perUnitV(DataframeContext dataframeContext, ThreeWindingsTr
return perUnitV(dataframeContext, leg.getRatedU(), leg.getTerminal());
}

public static double perUnitTargetV(DataframeContext dataframeContext, double v, Terminal distantTerminal, Terminal localTerminal) {
if (distantTerminal != null) {
return perUnitV(dataframeContext, v, distantTerminal);
} else {
return perUnitV(dataframeContext, v, localTerminal);
}
}

public static double perUnitV(DataframeContext dataframeContext, double v, Terminal terminal) {
if (terminal == null) {
throw new PowsyblException("terminal not found for per unit V");
if (dataframeContext.isPerUnit()) {
throw new PowsyblException("terminal not found for per unit V");
} else {
return v;
}
}
return perUnitV(dataframeContext, v, terminal.getVoltageLevel().getNominalV());
}
Expand Down
2 changes: 1 addition & 1 deletion tests/test_network.py
Original file line number Diff line number Diff line change
Expand Up @@ -1828,7 +1828,7 @@ def test_ratio_tap_changer_regulated_side():
assert not tap_changer.regulating
assert tap_changer.regulated_side == ''

with pytest.raises(pp.PyPowsyblError, match='terminal not found for un per unit V'):
with pytest.raises(pp.PyPowsyblError, match='a regulation terminal has to be set'):
n.update_ratio_tap_changers(id='T4-1-0', target_v=100, regulating=True)

with pytest.raises(pp.PyPowsyblError, match='must be ONE or TWO'):
Expand Down