Notifications
You must be signed in to change notification settings - Fork 157
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Support graceful connection close #1181
Comments
I'm not familiar enough with the code to know the answer to this, but I'm happy to review a patch if you research it. |
Code in question: https://github.com/python-hyper/hyper-h2/blob/570dc7daa480d34bcf0676e88d241112c51b1796/h2/connection.py#L1825-L1844 TL;DR as far as I understand the RFC:
Cross-link: https://github.com/encode/httpx/issues/828 |
Would it help to split the input two ways:
|
Any updates on this? |
I've looked at fixing this and it seems like it'd be a lot of work. I'm very hesitant to dig into it without guidance from maintainers. It seems this is further complicated by two-stage GOAWAY handling but that does not appear to be well supported in general, for example https://mailman.nginx.org/pipermail/nginx-devel/2021-April/013956.html. |
RFC 7540 section 6.8 seems to indicate that traffic can continue flowing in both directions after a GOAWAY frame, with the only restriction being that the recipient can't open new streams after receiving the GOAWAY:
But, h2's connection state machine immediately transitions to CLOSED upon sending or receiving a GOAWAY, effectively prohibiting any further traffic. Would you be interested in a patch to fix this, or is there some disconnect I'm missing between the wording of the RFC and actual implementations?
The text was updated successfully, but these errors were encountered: