Notifications
You must be signed in to change notification settings - Fork 63
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Added support for X3 Hybrid G4 (#100)
* Added support for X3 Hybrid G4 * Fixed regression in to_signed * Fixed whitespace * Limited connection variants for X3HybridG4 * Fixed formating * Fixed tests
- Loading branch information
1 parent
5c5097e
commit 5fdb6d1
Showing
9 changed files
with
488 additions
and
3 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,93 @@ | ||
import voluptuous as vol | ||
|
||
from solax.inverter import Inverter | ||
from solax.units import Total, Units | ||
from solax.utils import div10, div100, pack_u16, to_signed, to_signed32, twoway_div10 | ||
|
||
|
||
class X3HybridG4(Inverter): | ||
"""X3 Hybrid G4 v3.006.04""" | ||
|
||
# pylint: disable=duplicate-code | ||
_schema = vol.Schema( | ||
{ | ||
vol.Required("type"): vol.All(int, 14), | ||
vol.Required("sn"): str, | ||
vol.Required("ver"): str, | ||
vol.Required("Data"): vol.Schema( | ||
vol.All( | ||
[vol.Coerce(float)], | ||
vol.Length(min=300, max=300), | ||
) | ||
), | ||
vol.Required("Information"): vol.Schema( | ||
vol.All(vol.Length(min=10, max=10)) | ||
), | ||
}, | ||
extra=vol.REMOVE_EXTRA, | ||
) | ||
|
||
@classmethod | ||
def build_all_variants(cls, host, port, pwd=""): | ||
return [cls._build(host, port, pwd, False)] | ||
|
||
@classmethod | ||
def _decode_run_mode(cls, run_mode): | ||
return { | ||
0: "Waiting", | ||
1: "Checking", | ||
2: "Normal", | ||
3: "Fault", | ||
4: "Permanent Fault", | ||
5: "Updating", | ||
6: "EPS Check", | ||
7: "EPS Mode", | ||
8: "Self Test", | ||
9: "Idle", | ||
10: "Standby", | ||
}.get(run_mode) | ||
|
||
@classmethod | ||
def response_decoder(cls): | ||
return { | ||
"Grid 1 Voltage": (0, Units.V, div10), | ||
"Grid 2 Voltage": (1, Units.V, div10), | ||
"Grid 3 Voltage": (2, Units.V, div10), | ||
"Grid 1 Current": (3, Units.A, twoway_div10), | ||
"Grid 2 Current": (4, Units.A, twoway_div10), | ||
"Grid 3 Current": (5, Units.A, twoway_div10), | ||
"Grid 1 Power": (6, Units.W, to_signed), | ||
"Grid 2 Power": (7, Units.W, to_signed), | ||
"Grid 3 Power": (8, Units.W, to_signed), | ||
"PV1 Voltage": (10, Units.V, div10), | ||
"PV2 Voltage": (11, Units.V, div10), | ||
"PV1 Current": (12, Units.A, div10), | ||
"PV2 Current": (13, Units.A, div10), | ||
"PV1 Power": (14, Units.W), | ||
"PV2 Power": (15, Units.W), | ||
"Grid 1 Frequency": (16, Units.HZ, div100), | ||
"Grid 2 Frequency": (17, Units.HZ, div100), | ||
"Grid 3 Frequency": (18, Units.HZ, div100), | ||
"Run mode": (19, Units.NONE), | ||
"Run mode text": (19, Units.NONE, X3HybridG4._decode_run_mode), | ||
"EPS 1 Voltage": (23, Units.W, div10), | ||
"EPS 2 Voltage": (24, Units.W, div10), | ||
"EPS 3 Voltage": (25, Units.W, div10), | ||
"EPS 1 Current": (26, Units.W, twoway_div10), | ||
"EPS 2 Current": (27, Units.W, twoway_div10), | ||
"EPS 3 Current": (28, Units.W, twoway_div10), | ||
"EPS 1 Power": (29, Units.W, to_signed), | ||
"EPS 2 Power": (30, Units.W, to_signed), | ||
"EPS 3 Power": (31, Units.W, to_signed), | ||
"Feed-in Power ": (pack_u16(34, 35), Units.W, to_signed32), | ||
"Battery Power": (41, Units.W, to_signed), | ||
"Yield total": (pack_u16(68, 69), Total(Units.KWH), div10), | ||
"Yield today": (70, Units.KWH, div10), | ||
"Feed-in Energy": (pack_u16(86, 87), Total(Units.KWH), div100), | ||
"Consumed Energy": (pack_u16(88, 89), Total(Units.KWH), div100), | ||
"Battery Remaining Capacity": (103, Units.PERCENT), | ||
"Battery Temperature": (105, Units.C, to_signed), | ||
"Battery Voltage": (pack_u16(169, 170), Units.V, div100), | ||
} | ||
|
||
# pylint: enable=duplicate-code |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.