Skip to content

The shell + Perl files from my CO2NSL project done @DTU.dk in 2012

License

Notifications You must be signed in to change notification settings

sunadtudk/BeagleBone_DAQ

Repository files navigation

BeagleBone_DAQ

Project Website : http://deadmeat.dk/co2nsl/

The code from my Master Project done @ DTU 2012.

Abstract The following report will describe the development of a computer system, and act as the final exams project for Sune Andersen prepared at Informatics Mathematical Modelling, the Technical University of Denmark acquiring the candidate degree in computer engineering. The project lasts 26 weeks, which must cover analyses, design, implementation and documentation of the project. Risø National Laboratory is getting more and more requests from The danish government on how to save energy. One of the main issue is saving money on power,special when it comes to streetlight. Before the end of the year 2012,1500 street lamps around Copenhagen will be changed for light sources with low power consumption. Technical and Environmental turn down the energy as a part of Copenhagen goal of reducing the citys CO2 emissions by 20 percent by the end of year 2015. But how much power will the new lamps comsume? And can a street lamp produce sufficient power even in Denmark?. Here will a low cost & lowpower Datalogger come handy. The data logger is an electronic device that records earthquakes(Sensor network), Wind ,daylight ,power used/produced on the street lamp over time. Data will then be uploaded via a wireless radio MESH network(868 Mhz) to a database server for later analyze. The Prototype is developed on two microcontrollers(AVR and ARM Cortex-A8) with the low power and with fault tolerant in mind, equipped with extra storage for offline catching(like a uSD(16/32Gb)). The ARM CortexA8-board is running a full version of Ubuntu(OMAP), with Apache-webserver,PHP and MySQL-database for local catching of data, in case of the network is offline. Data will then be sync with the database server then there is connectivity. Controlling the Datalogger device can be done from the control centers webinterface or on the device it self(via Web or SSH). The device can even be used for other purposes like a (MESH) WIFI net, something like freifunk in Berlin & WNDW. In a catastrophe area the lamp-network will still be running (because it is off-grid), even when the infrastructure is destroyed or very heavy loaded.

#Type Master's thesis [Academic thesis] #Year 2012 #Publisher Technical University of Denmark, DTU Informatics, E-mail: [email protected]

More info : http://www2.imm.dtu.dk/pubdb/views/publication_details.php?id=6410

About

The shell + Perl files from my CO2NSL project done @DTU.dk in 2012

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published