MQTT Remote Control
MQTT Remote Control enables controlling BPL by a MQTT server. When enabled, BPL subscribes the specified path and changes the setting accordingly. Currently, four item can be controlled in this way:
The values can be 0,1,2,3 or o,f,b,p for 'Off', 'Fridge Constant', 'Beer Constant', and 'Beer Profile'. If the mode is changed to 'Beer Profile', the current profile will be used and the profile starting time will be set to current time. That is, you should edit the profile beforehand, and expect the profile to be execute starting from the time it is set.
It is valid in 'Fridge Constant' and 'Beer Constant' mode only.
To set PTC target temperature, the 'triggering temperature' will set to 3 degree higher.
Connecting to MQTT server takes up a TCP connection and some resource. The program might stick to the setting on MQTT server. Therefore, enable it only when you need it.
There is latency of network and update of data. Therefore, expect some delay after changing the setting.
Wiki is deprecated. Check doc directory for latest document. https://github.com/vitotai/BrewPiLess/tree/master/doc
- Hardware Setup
- Localization of web frontend
- Flash layout and New Frontend
- Software Installation
- WiFi Setup
- System Setup
- Device Setup
- Using Buttons & Menu
- Temperature Logging
- Cloud Logging
- Beer Profile
- iSpindel Support
- Manual Gravity Logging
- Use with Glycol
- Auto Capping(Spunding)
- MQTT Remote Control
- Pressure Monitor and Control
-
Other URLs
- Clear WiFi setting
- Format file system
- OTA update
- Overwrite pages
-
JSON Commands
- Temperature Unit
- Sensor Calibration
- FAQ