-- TI BQ40Z BMS shutdown script | ||
---@diagnostic disable: param-type-mismatch | ||
|
||
local mavlink_msgs = require("MAVLink/mavlink_msgs") | ||
|
||
local COMMAND_ACK_ID = mavlink_msgs.get_msgid("COMMAND_ACK") | ||
local COMMAND_LONG_ID = mavlink_msgs.get_msgid("COMMAND_LONG") | ||
local msg_map = {} | ||
msg_map[COMMAND_ACK_ID] = "COMMAND_ACK" | ||
msg_map[COMMAND_LONG_ID] = "COMMAND_LONG" | ||
|
||
local PARAM_TABLE_KEY = 51 | ||
local PARAM_TABLE_PREFIX = "BATT_BQ40Z_" | ||
-- add a parameter and bind it to a variable | ||
function bind_add_param(name, idx, default_value) | ||
assert(param:add_param(PARAM_TABLE_KEY, idx, name, default_value), string.format('could not add param %s', name)) | ||
return Parameter(PARAM_TABLE_PREFIX .. name) | ||
end | ||
assert(param:add_table(PARAM_TABLE_KEY, PARAM_TABLE_PREFIX, 2), 'could not add param table') | ||
--[[ | ||
// @Param: BATT_BQ40Z_BUS | ||
// @DisplayName: Bus number for the BQ40Z | ||
// @Description: Bus number for the BQ40Z | ||
// @Range: 0 3 | ||
// @User: Standard | ||
--]] | ||
local BATT_BQ40Z_BUS = bind_add_param('BUS', 1, 0) | ||
|
||
|
||
-- Initialize MAVLink rx with number of messages, and buffer depth | ||
mavlink:init(1, 10) | ||
|
||
-- Register message id to receive | ||
mavlink:register_rx_msgid(COMMAND_LONG_ID) | ||
|
||
local MAV_CMD_PREFLIGHT_REBOOT_SHUTDOWN = 246 | ||
local MAV_RESULT_ACCEPTED = 0 | ||
|
||
-- Init BMS i2c device | ||
assert(BATT_BQ40Z_BUS ~= nil, "BATT_BQ40Z_BUS not configured properly") | ||
assert(BATT_BQ40Z_BUS:get() ~= nil, "BATT_BQ40Z_BUS not retrievable") | ||
local bms = i2c:get_device(math.floor(BATT_BQ40Z_BUS:get()), 0x0B) | ||
assert(bms ~= nil, "BQ40Z bms script cant create i2c device") | ||
|
||
-- Exit emergency shutdown (for BQ40Z60, twice for redundancy) | ||
bms:transfer(string.pack("BBB", 0x00, 0xA7, 0x23), 0) | ||
bms:transfer(string.pack("BBB", 0x00, 0xA7, 0x23), 0) | ||
|
||
-- Function that is returned to the AP scheduler when we want to shutdown | ||
function shutdown_loop() | ||
local ret = bms:transfer(string.pack("BBB", 0x00, 0x10, 0x00), 0) | ||
if ret == nil then | ||
gcs:send_text(0, "BQ40Z shutdown transfer failed") | ||
end | ||
|
||
return shutdown_loop, 500 | ||
end | ||
|
||
-- Main loop | ||
function update() | ||
local msg, chan = mavlink:receive_chan() | ||
local parsed_msg = nil | ||
|
||
if (msg ~= nil) then | ||
parsed_msg = mavlink_msgs.decode(msg, msg_map) | ||
end | ||
|
||
if parsed_msg ~= nil and (parsed_msg.msgid == COMMAND_LONG_ID) and (parsed_msg.command == MAV_CMD_PREFLIGHT_REBOOT_SHUTDOWN) then | ||
gcs:send_text(0, "Got MAV_CMD_PREFLIGHT_REBOOT_SHUTDOWN") | ||
|
||
if parsed_msg.param1 == 2 then | ||
gcs:send_text(0, "Shutting down BQ40Z!!!") | ||
|
||
-- Send ack | ||
local ack = {} | ||
ack.command = parsed_msg.command | ||
ack.result = MAV_RESULT_ACCEPTED | ||
ack.progress = 0 | ||
ack.result_param2 = 0 | ||
ack.target_system = parsed_msg.sysid | ||
ack.target_component = parsed_msg.compid | ||
mavlink:send_chan(chan, mavlink_msgs.encode("COMMAND_ACK", ack)) | ||
|
||
-- Shutdown | ||
return shutdown_loop, 0 | ||
end | ||
end | ||
|
||
return update, 1000 | ||
end | ||
|
||
|
||
return update, 1000 |