AP_Scripting: added get_cell_voltage() API and arming check example
Browse files Browse the repository at this point in the history
this allows for cell imbalance to be checked as an arming check using
a lua script
  • Loading branch information
tridge committed Oct 23, 2023
1 parent b197f11 commit 50096dc
Show file tree
Hide file tree
Showing 3 changed files with 55 additions and 0 deletions.
6 changes: 6 additions & 0 deletions libraries/AP_Scripting/docs/docs.lua
Original file line number Diff line number Diff line change
Expand Up @@ -2718,6 +2718,12 @@ function battery:healthy(instance) end
---@return integer
function battery:num_instances() end

-- get individual cell voltage
---@param instance integer
---@param cell integer
---@return number|nil
function battery:get_cell_voltage(instance, cell) end


-- desc
---@class arming
Expand Down
48 changes: 48 additions & 0 deletions libraries/AP_Scripting/examples/cell_balance_check.lua
Original file line number Diff line number Diff line change
@@ -0,0 +1,48 @@
--[[
script implementing pre-arm check that batteries are well balanced
--]]

local MAX_CELL_DEVIATION = 0.2

local auth_id = arming:get_aux_auth_id()

local NCELLS_MAX = 16

function check_cell_balance(bnum)
local min_volt = -1
local max_volt = -1
for c=0,NCELLS_MAX do
local voltage = battery:get_cell_voltage(bnum, c)
if not voltage then
break
end
if min_volt == -1 or min_volt > voltage then
min_volt = voltage
end
if max_volt == -1 or max_volt < voltage then
max_volt = voltage
end
end
local vdiff = max_volt - min_volt
if vdiff > MAX_CELL_DEVIATION then
arming:set_aux_auth_failed(auth_id, string.format("Batt[%u] imbalance %.1fV", bnum+1, vdiff))
return false
end
return true
end

function update()
local num_batts = battery:num_instances()
local ok = true
for i=0,num_batts do
if not check_cell_balance(i) then
ok = false
end
end
if ok then
arming:set_aux_auth_passed(auth_id)
end
return update, 500
end

return update()
1 change: 1 addition & 0 deletions libraries/AP_Scripting/generator/description/bindings.desc
Original file line number Diff line number Diff line change
Expand Up @@ -90,6 +90,7 @@ singleton AP_BattMonitor method overpower_detected boolean uint8_t 0 ud->num_ins
singleton AP_BattMonitor method get_temperature boolean float'Null uint8_t 0 ud->num_instances()
singleton AP_BattMonitor method get_cycle_count boolean uint8_t 0 ud->num_instances() uint16_t'Null
singleton AP_BattMonitor method reset_remaining boolean uint8_t 0 ud->num_instances() float 0 100
singleton AP_BattMonitor method get_cell_voltage boolean uint8_t'skip_check uint8_t'skip_check float'Null

include AP_GPS/AP_GPS.h

Expand Down

0 comments on commit 50096dc