Conversation
This looks like a fantastic improvement for both the stereo calibration accuracy and convenience of the calibration workflow. Thank you! The new logic does not seem to share data collected in one step (e.g. left) with other ones (right and stereo), though. Have you considered adding this? I think this could make the calibration process much faster.
This would be a very useful option to have as well. |
Also, if the monocular calibrations are available, then the |
I am not completely sure how I would go about this, although I do agree that anything we can do to reduce the optimization time would be very helpful. Currently, the
Good point, the major difficulty with running the stereo calibration tool for minimal overlapping FOV is simply getting |
@phil0stine - Please rebase on |
0057db6
to
fbf954d
Compare
…o calibration for a camera pair
@JWhitleyAStuff Rebased. I had to resolve some conflicts and haven't had a chance to test again, but I think it's ready to go. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
LGTM. Will probably hold merge until another test is complete.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Yeah, I'd like an independent person to verify
Been holding for testing for a couple of years now. @phil0stine Are you able to test this and/or still want it merged? |
@JWhitleyWork Yes this would still be useful to merge. I will update the PR, re-test and let you know when it's ready |
Adds an optional flag to allow user to do a good monocular calibration of each camera of a stereo pair independently, then fix those values for the stereo calibration between them, with the
--mono-before-stereo
flag.Currently, each camera is independently calibrated, using only the corners that were valid for both cameras during the stereo data collection. For wider baselines, this means that the non-overlapping portions of each camera's image will have no valid data but will still be used to overwrite any existing monocular calibration.
One option to address this would be to also listen for
camera_info
messages and provide a flag to use that intrinsic information for the stereo calibration.This PR instead combines the 3 calibration processes into one; first, data for the left mono camera is collected, then the right mono camera, and finally the stereo pair. The UI updates for each step; and the monocular calibrations are deferred until the end to save the user lots of time waiting for each mono to complete.
I have tested this primarily on version 1.12.23 with ROS melodic, and have seen some lagginess issues using the
--approximate
flag on version 1.13.0, but I don't see how it would be related to these changes.