Skip to content

packet_link_qualification_test

Github Action edited this page May 1, 2024 · 6 revisions

gNOI-2.1: Packet-based Link Qualification

Summary

Validate gNOI RPC can support packet-based link qualification test for the links between 2 DUTs.

Topology

  • dut1:port1 <--> port1:dut2

Procedure

  • Connect two vendor devices back to back on 100G bandwidth ports.
    • Validate the link qualification Capabilities response.
      • MaxHistoricalResultsPerInterface is >= 2.
      • Time exists.
      • Generator:
        • MinMtu >= 64,
        • MaxMtu >= 8184,
        • MaxBps >= 4e11,
        • MaxPps >= 5e8,
        • MinSetupDuration > 0
        • MinTeardownDuration > 0,
        • MinSampleInterval > 0,
      • Reflector:
        • MinSetupDuration > 0
        • MinTeardownDuration > 0,
  • Validate the error code is returned for Get and Delete requests with non-existing ID.
    • Error code is 5 NOT_FOUND (HTTP Mapping: 404 Not Found).
  • Validate the link qualification List and Delete.
    • Issue List qualifications request.
    • Delete the qualification if qualification is found.
    • Issue List qualifications request again.
    • Verify that the qualification has been deleted successfully by checking List response.
  • Set a device as the NEAR_END (generator) device for Packet Based Link Qual.
    • Issue gnoi.LinkQualification Create RPC to the device and provide following parameters:
      • Id: A unique identifier for this run of the test
      • InterfaceName: interface as the interface to be used as generator end.
        • This interface must be connected to the interface chosen on the reflector device using 100G connection.
      • EndpointType: Qualification_end set as NEAR_END with PacketGeneratorConfiguration.
    • Set the following parameters for link qualification service usage:
      • PacketRate: Packet per second rate to use for this test.
      • PacketSize: Size of packets to inject. The value is 8184 bytes.
    • RPCSyncedTiming:
      • SetupDuration: The requested setup time for the endpoint.
      • PreSyncDuration: Minimum_wait_before_preparation_seconds. Within this period, the device should:
        • Initialize the link qualification state machine.
        • Set port’s state to TESTING. This state is only relevant inside the linkQual service.
        • Set the port in loopback mode.
      • Duration:The length of the qualification.
      • PostSyncDuration: The amount time a side should wait before starting its teardown.
      • TeardownDuration: The amount time required to bring the interface back to pre-test state.
    •   Verify generator interface oper-state is 'TESTING'
      
  • Set another device as the FAR_END (reflector) device for Packet Based Link Qual.
    • Issue gnoi.LinkQualification Create RPC to the device and provide following parameters:
      • Id: A unique identifier for this run of the test
      • InterfaceName: Interface as the interface to be used as a reflector to turn the packet back.
      • EndpointType: Qualification_end set as FAR_END.
      • RPCSyncedTiming:
        • Reflector timers should be same as the ones on the generator.
      • Verify reflector interface oper-state is 'TESTING'
  • Get the result by issuing gnoi.LinkQualification Get RPC to gather the result of link qualification. Provide the following parameter:
    • Id: The identifier used above on the NEAR_END side.
    • Validate the response to
      • Ensure that the current_state is QUALIFICATION_STATE_COMPLETED
      • Ensure that the num_corrupt_packets and num_packets_dropped_by_mmu are 0
      • Ensure that RPC status code is 0 for succuss.
      • Packets sent count matches with packets received.

OpenConfig Path and RPC Coverage

The below yaml defines the OC paths intended to be covered by this test. OC paths used for test setup are not listed here.

rpcs:
  gnoi:
    packet_link_qualification.LinkQualification.Capabilities:
    packet_link_qualification.LinkQualification.Create:
    packet_link_qualification.LinkQualification.Delete:
    packet_link_qualification.LinkQualification.Get:
    packet_link_qualification.LinkQualification.List:
Clone this wiki locally