-
Notifications
You must be signed in to change notification settings - Fork 1
Run the no‐OS Demonstration Standalone (AD7606B)
In addition to the DataStorm DAQ development kit running either in standalone mode or remotely via Ethernet cable, it can also run for no-OS software while connected to computer via an usb cable.
The AD7606B Evaluation Platform in this configuration is comprised of the following components:
- Analog Devices EVAL-AD7606BFMCZ (also Known As EVAL-AD7606B) data converter board
- DataStorm DAQ (Trenz Intel® Cyclone® V SoC TEI0022 Development Board) (includes 12VDC power supply)
- Digilent Analog Discovery 2 Signal Generator with dual outputs
- Digilent Discovery BNC adapter board
- Two (2) BNC Male to SMB Female Cables
- USB connectors
- Separate Windows PC running Digilent WaveForms App and Terminal Program
Select the SD card as the boot source for the processor.
The FMC_VADJ power rails provide power to the EVAL-AD7606BFMCZ via the FMC interface. This is an adjustable voltage. It must be set to 3.3V. Modify the VID_SW DIP switch settings to select 3.3V.
Follow the steps in the order shown below.
- Insert the Micro SD card into the SD card slot
- Insert the EVAL-AD7606BFMCZ FMC connector into the FMC mating connector on the DataStorm DAQ board
- Connect the Signal Generator to the EVAL-AD7606BFMCZ SMA connectors
- Ensure that Jumper JP5 is removed, Jumper JP1 is in position A to remove standby, Jumper JP6 is in position B to get internal voltage reference on AD7606B, Jumper JP3 in position B, and Jumper JP2 is in position A to get +12V from FMC on the EVAL-AD7606BFMCZ board, for it to be powered via the FMC connector.
- Connect the power supply to the DataStorm DAQ
- Plug the AC-DC adapter into an AC outlet
The Analog Discovery 2 is used as a signal generator to drive the AD7606B input.
Install (if not already done) the Digilent WaveForms App.
Open the WaveForms App and Click on Wavegen in the left margin which opens a waveform window
Click on Channels and select 1
Select Type as Sine
Select Frequency or Period
Set Amplitude to 1V
Set Offset to 0V
Click Run All
There are a few software components that need to be installed in order to run this demo successfully:
- A SW terminal like Tera Term VT or Putty
- A wired Micro USB serial port connection between the separate Windows PC and the embedded target is required
- Launch a terminal program like Tera Term VT or Putty and connect via a serial port to interact with the demo
- Select 115200 baud
- Select the appropriate target COM port
Simply power up the unit. No additional configuration is required. The bare metal application runs automatically and continuously streams analog measurement results across the serial port to be received and displayed in the terminal program running on the separate Windows PC.
Serial Interface
Parallel Interface
NOTE: HDL design for AD7606B is based on 4-SDI lane for all channels to receive at throughput 800Ksps in Serial interface. The no-OS example supports only for 4-SDI lane.
Return to AD7606B Quick Start Guide
Please click Here to purchase platform boards
Arrow Data Storm DAQ Development Platform
Introduction
Developer Starter Guides
Additional Developer Docs
AD40xx Platform User Guide
AD7768 Platform User Guide
AD7768-1 Platform User Guide
AD7606B Platform User Guide
AD738x Platform User Guide
AD469x Platform User Guide
AD463x Platform User Guide
ADRV9001/2 Platform User Guide